Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -761,12 +761,12 @@ 761 761 762 762 In this section: 763 763 764 -* **Enable**– a flag to enable the cooler control;765 -* **Maximum cell temperature**, °C;766 -* **Tolerant cell temperature**, °C;767 -* **Delay before starting the cooler**, millisecond;768 -* **Delay before stopping the cooler**, millisecond;769 -* **Errors 1, 2 to open the cooler**– bitfields to choose the errors which will open thecooler.764 +* Enable – a flag to enable the cooler control; 765 +* Maximum cell temperature, °C; 766 +* Tolerant cell temperature, °C; 767 +* Delay before starting the cooler, millisecond; 768 +* Delay before stopping the cooler, millisecond; 769 +* **Errors 1, 2 to open the heater** – bitfields to choose the errors which will open the heater. 770 770 771 771 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 772 772 ... ... @@ -787,11 +787,6 @@ 787 787 788 788 === High voltage === 789 789 790 -(% class="box infomessage" %) 791 -((( 792 -This section is not available on BMS Main 2R. 793 -))) 794 - 795 795 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 796 796 797 797 To change the parameters of high voltage fault, select the "Control → High voltage" section: ... ... @@ -800,9 +800,9 @@ 800 800 801 801 In this section: 802 802 803 -* **Enable**– a flag to enable High voltage control;804 -* **Delay before clearing the High voltage fault**, second;805 -* **Lock the High voltage fault**.798 +* Enable – a flag to enable High voltage control; 799 +* Delay before clearing the High voltage fault, second; 800 +* Lock the High voltage fault. 806 806 807 807 The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated. 808 808 ... ... @@ -815,7 +815,7 @@ 815 815 816 816 The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level. 817 817 818 -The BMS Main 3 / BMS Main 2Rdevice can automatically determine the battery discharge characteristic.813 +The BMS Main 3 device can automatically determine the battery discharge characteristic. 819 819 820 820 Before starting the process of determining the discharge characteristic, it is necessary to prepare a BMS: 821 821 ... ... @@ -828,14 +828,16 @@ 828 828 829 829 In this section: 830 830 831 -* **Enable**– a flag to enable cell analysis;832 -* **Discharge step**, Ah;833 -* **Delta voltage**– a maximum allowable voltage drop for the cell, V;834 -* **Logic index, Cell index**– a position of the analyzed cell;835 -* **Analyse the most discharged cell**– a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored).826 +* Enable – a flag to enable cell analysis; 827 +* Discharge step, Ah; 828 +* Delta voltage – a maximum allowable voltage drop for the cell, V; 829 +* Logic index, Cell index – a position of the analyzed cell; 830 +* Analyse the most discharged cell – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored). 836 836 837 -Discharge step should be set equal to С/21,832 +Discharge step should be set equal to 838 838 834 +Discharge step= С/21, 835 + 839 839 where C is the cell capacity. 840 840 841 841 The discharge characteristic will be constructed for the given cell (its position is determined by the fields “Logic index” and “Cell index”).