Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -741,12 +741,11 @@ 741 741 Conditions for signal generation: 742 742 743 743 * the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time; 744 -* there are no errors from "Errors 1, 2..." bitfields.744 +* there are no errors from** Errors 1, 2** 745 745 746 746 Conditions for clearing the signal: 747 747 748 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time; 749 -* there is an error from "Errors 1, 2..." bitfields. 748 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 750 750 751 751 (% class="box infomessage" %) 752 752 ((( ... ... @@ -761,24 +761,22 @@ 761 761 762 762 In this section: 763 763 764 -* **Enable**– a flag to enable the cooler control;765 -* **Maximum cell temperature**, °C;766 -* **Tolerant cell temperature**, °C;767 -* **Delay before starting the cooler**, millisecond;768 -* **Delay before stopping the cooler**, millisecond;769 -* **Errors 1, 2toopenthe cooler**– bitfieldstochoosethe errorswhich willopenthecooler.763 +* Enable – a flag to enable the cooler control; 764 +* Maximum cell temperature, °C; 765 +* Tolerant cell temperature, °C; 766 +* Delay before starting the cooler, millisecond; 767 +* Delay before stopping the cooler, millisecond; 768 +* Switch off the cooler contactor on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 770 770 771 771 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 772 772 773 773 Conditions for signal generation: 774 774 775 -* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time; 776 -* there are no errors from "Errors 1, 2..." bitfields. 774 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time. 777 777 778 778 Conditions for clearing the signal: 779 779 780 -* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time; 781 -* there is an error from "Errors 1, 2..." bitfields. 778 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 782 782 783 783 (% class="box infomessage" %) 784 784 ((( ... ... @@ -787,7 +787,6 @@ 787 787 788 788 === High voltage === 789 789 790 - 791 791 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 792 792 793 793 To change the parameters of high voltage fault, select the "Control → High voltage" section: