... ... @@ -761,12 +761,12 @@ 761 761 762 762 In this section: 763 763 764 -* Enable – a flag to enable the cooler control; 765 -* Maximum cell temperature, °C; 766 -* Tolerant cell temperature, °C; 767 -* Delay before starting the cooler, millisecond; 768 -* Delay before stopping the cooler, millisecond; 769 -* **Errors 1, 2 to open the heater**– bitfields to choose the errors which will open theheater.764 +* **Enable** – a flag to enable the cooler control; 765 +* **Maximum cell temperature**, °C; 766 +* **Tolerant cell temperature**, °C; 767 +* **Delay before starting the cooler**, millisecond; 768 +* **Delay before stopping the cooler**, millisecond; 769 +* **Errors 1, 2 to open the cooler **– bitfields to choose the errors which will open the cooler. 770 770 771 771 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 772 772 ... ... @@ -787,6 +787,11 @@ 787 787 788 788 === High voltage === 789 789 790 +(% class="box infomessage" %) 791 +((( 792 +This section is not available on BMS Main 2R. 793 +))) 794 + 790 790 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 791 791 792 792 To change the parameters of high voltage fault, select the "Control → High voltage" section: ... ... @@ -795,9 +795,9 @@ 795 795 796 796 In this section: 797 797 798 -* Enable – a flag to enable High voltage control; 799 -* Delay before clearing the High voltage fault, second; 800 -* Lock the High voltage fault. 803 +* **Enable **– a flag to enable High voltage control; 804 +* **Delay before clearing the High voltage fault**, second; 805 +* **Lock the High voltage fault**. 801 801 802 802 The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated. 803 803 ... ... @@ -810,7 +810,7 @@ 810 810 811 811 The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level. 812 812 813 -The BMS Main 3 device can automatically determine the battery discharge characteristic. 818 +The BMS Main 3 / BMS Main 2R device can automatically determine the battery discharge characteristic. 814 814 815 815 Before starting the process of determining the discharge characteristic, it is necessary to prepare a BMS: 816 816 ... ... @@ -823,18 +823,14 @@ 823 823 824 824 In this section: 825 825 826 -* Enable – a flag to enable cell analysis; 827 -* Discharge step, Ah; 828 -* Delta voltage – a maximum allowable voltage drop for the cell, V; 829 -* Logic index, Cell index – a position of the analyzed cell; 830 -* Analyse the most discharged cell – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored). 831 +* **Enable **– a flag to enable cell analysis; 832 +* **Discharge step**, Ah; 833 +* **Delta voltage** – a maximum allowable voltage drop for the cell, V; 834 +* **Logic index, Cell index** – a position of the analyzed cell; 835 +* **Analyse the most discharged cell** – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored). 831 831 832 -Discharge step should be set equal to 837 +Discharge step should be set equal to С/21, where C is the cell capacity. 833 833 834 -Discharge step= С/21, 835 - 836 -where C is the cell capacity. 837 - 838 838 The discharge characteristic will be constructed for the given cell (its position is determined by the fields “Logic index” and “Cell index”). 839 839 840 840 The algorithm for determining the discharge characteristic of the battery will be started if the “Enable” flag is set. From this moment, the control of the discharge contactor is performed by this algorithm.