Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -546,7 +546,7 @@ 546 546 547 547 Charge/Discharge contactor has three algorithms of operation: 548 548 549 -On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge algorithms andtheirsignalsand behaves549 +On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge controllers and behaves: 550 550 551 551 * as Charging contactor if "Charging" signal is set; 552 552 * as Discharging contactor in other cases. ... ... @@ -741,11 +741,12 @@ 741 741 Conditions for signal generation: 742 742 743 743 * the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time; 744 -* 744 +* there are no errors from "Errors 1, 2..." bitfields. 745 745 746 746 Conditions for clearing the signal: 747 747 748 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 748 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time; 749 +* there is an error from "Errors 1, 2..." bitfields. 749 749 750 750 (% class="box infomessage" %) 751 751 ((( ... ... @@ -760,22 +760,24 @@ 760 760 761 761 In this section: 762 762 763 -* Enable – a flag to enable the cooler control; 764 -* Maximum cell temperature, °C; 765 -* Tolerant cell temperature, °C; 766 -* Delay before starting the cooler, millisecond; 767 -* Delay before stopping the cooler, millisecond; 768 -* Switchoffthe coolercontactoron errors(Undervoltage,Overcurrent, Low temperature,Short circuitorCriticalerror).764 +* **Enable** – a flag to enable the cooler control; 765 +* **Maximum cell temperature**, °C; 766 +* **Tolerant cell temperature**, °C; 767 +* **Delay before starting the cooler**, millisecond; 768 +* **Delay before stopping the cooler**, millisecond; 769 +* **Errors 1, 2 to open the cooler **– bitfields to choose the errors which will open the cooler. 769 769 770 770 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 771 771 772 772 Conditions for signal generation: 773 773 774 -* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time. 775 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time; 776 +* there are no errors from "Errors 1, 2..." bitfields. 775 775 776 776 Conditions for clearing the signal: 777 777 778 -* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 780 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time; 781 +* there is an error from "Errors 1, 2..." bitfields. 779 779 780 780 (% class="box infomessage" %) 781 781 ((( ... ... @@ -784,6 +784,7 @@ 784 784 785 785 === High voltage === 786 786 790 + 787 787 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 788 788 789 789 To change the parameters of high voltage fault, select the "Control → High voltage" section: