Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -560,8 +560,9 @@ 560 560 561 561 the charging/discharging contactor opens. 562 562 563 -On **Independent (on Charge request or Discharge request)** algorithm charge/discharge contactor is based on its own controller and performs as follows: 564 564 564 +**Independent (on Charge request or Discharge request)** - charge/discharge contactor is based on its own controller and performs as follows: 565 + 565 565 * if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging/discharging contactor closes; 566 566 * If the "Charge request" or "Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the charging/discharging contactor opens. 567 567 ... ... @@ -734,14 +734,13 @@ 734 734 * **Tolerant cell temperature**, °C; 735 735 * **Delay before starting the heater**, millisecond; 736 736 * **Delay before stopping the heater**, millisecond; 737 -* ** Errors 1, 2toopenthe heater**–bitfieldstochoose theerrorswhich willopentheheater.738 +* **Switch off the heater on errors** – switch off the Heater Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 738 738 739 739 As a result of operating the heating algorithm, the “Heater” signal is generated. 740 740 741 741 Conditions for signal generation: 742 742 743 -* the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time; 744 -* 744 +* the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time. 745 745 746 746 Conditions for clearing the signal: 747 747