717 717  In this section:
718 718  
719 719  * **Minimum voltage to power down** – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V;
720 -* **Idle time to power down** – a time of battery inactivity after which the battery is shut down, minute;
721 -* **Wait the "Power up/down request" is cleared (on startup)** – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS.
722 -* **Power down if KEYRUN and CHARGE_ON are cleared** – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared;
723 -* **Delay before setting the internal power down signal** – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms.
720 +* Idle time to power down – a time of battery inactivity after which the battery is shut down, minute;
721 +* Wait the "Power up/down request" is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS.
722 +* Power down if KEYRUN and CHARGE_ON are cleared – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared;
723 +* Delay before setting the internal power down signal – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms.
724 724  
725 725  === Heater ===
726 726  
... ... @@ -730,12 +730,12 @@
730 730  
731 731  In this section:
732 732  
733 -* **Enable **– a flag to enable the heater control;
734 -* **Minimum cell temperature**, °C;
735 -* **Tolerant cell temperature**, °C;
736 -* **Delay before starting the heater**, millisecond;
737 -* **Delay before stopping the heater**, millisecond;
738 -* **Switch off the heater on errors** – switch off the Heater Undervoltage, Overcurrent, High temperature, Short circuit or Critical error).
733 +* Enable – a flag to enable the heater control;
734 +* Minimum cell temperature, °C;
735 +* Tolerant cell temperature, °C;
736 +* Delay before starting the heater, millisecond;
737 +* Delay before stopping the heater, millisecond;
738 +* Switch off the heater on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error).
739 739  
740 740  As a result of operating the heating algorithm, the “Heater” signal is generated.
741 741