Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -546,7 +546,7 @@ 546 546 547 547 Charge/Discharge contactor has three algorithms of operation: 548 548 549 -On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge algorithms andtheirsignalsand behaves549 +On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge controllers and behaves: 550 550 551 551 * as Charging contactor if "Charging" signal is set; 552 552 * as Discharging contactor in other cases. ... ... @@ -560,9 +560,8 @@ 560 560 561 561 the charging/discharging contactor opens. 562 562 563 +On **Independent (on Charge request or Discharge request)** algorithm charge/discharge contactor is based on its own controller and performs as follows: 563 563 564 -**Independent (on Charge request or Discharge request)** - charge/discharge contactor is based on its own controller and performs as follows: 565 - 566 566 * if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging/discharging contactor closes; 567 567 * If the "Charge request" or "Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the charging/discharging contactor opens. 568 568 ... ... @@ -717,10 +717,10 @@ 717 717 In this section: 718 718 719 719 * **Minimum voltage to power down** – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 720 -* Idle time to power down – a time of battery inactivity after which the battery is shut down, minute; 721 -* Wait the "Power up/down request" is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS. 722 -* Power down if KEYRUN and CHARGE_ON are cleared – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared; 723 -* Delay before setting the internal power down signal – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms. 719 +* **Idle time to power down** – a time of battery inactivity after which the battery is shut down, minute; 720 +* **Wait the "Power up/down request" is cleared (on startup)** – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS. 721 +* **Power down if KEYRUN and CHARGE_ON are cleared** – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared; 722 +* **Delay before setting the internal power down signal** – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms. 724 724 725 725 === Heater === 726 726 ... ... @@ -730,22 +730,24 @@ 730 730 731 731 In this section: 732 732 733 -* Enable – a flag to enable the heater control; 734 -* Minimum cell temperature, °C; 735 -* Tolerant cell temperature, °C; 736 -* Delay before starting the heater, millisecond; 737 -* Delay before stopping the heater, millisecond; 738 -* Switchoffthe heateronerrors(Undervoltage,Overcurrent,Hightemperature, ShortcircuitorCriticalerror).732 +* **Enable **– a flag to enable the heater control; 733 +* **Minimum cell temperature**, °C; 734 +* **Tolerant cell temperature**, °C; 735 +* **Delay before starting the heater**, millisecond; 736 +* **Delay before stopping the heater**, millisecond; 737 +* **Errors 1, 2 to open the heater** – bitfields to choose the errors which will open the heater. 739 739 740 740 As a result of operating the heating algorithm, the “Heater” signal is generated. 741 741 742 742 Conditions for signal generation: 743 743 744 -* the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time. 743 +* the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time; 744 +* there are no errors from "Errors 1, 2..." bitfields. 745 745 746 746 Conditions for clearing the signal: 747 747 748 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 748 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time; 749 +* there is an error from "Errors 1, 2..." bitfields. 749 749 750 750 (% class="box infomessage" %) 751 751 ((( ... ... @@ -760,22 +760,24 @@ 760 760 761 761 In this section: 762 762 763 -* Enable – a flag to enable the cooler control; 764 -* Maximum cell temperature, °C; 765 -* Tolerant cell temperature, °C; 766 -* Delay before starting the cooler, millisecond; 767 -* Delay before stopping the cooler, millisecond; 768 -* Switchoffthe coolercontactoron errors(Undervoltage,Overcurrent, Low temperature,Short circuitorCriticalerror).764 +* **Enable** – a flag to enable the cooler control; 765 +* **Maximum cell temperature**, °C; 766 +* **Tolerant cell temperature**, °C; 767 +* **Delay before starting the cooler**, millisecond; 768 +* **Delay before stopping the cooler**, millisecond; 769 +* **Errors 1, 2 to open the cooler **– bitfields to choose the errors which will open the cooler. 769 769 770 770 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 771 771 772 772 Conditions for signal generation: 773 773 774 -* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time. 775 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time; 776 +* there are no errors from "Errors 1, 2..." bitfields. 775 775 776 776 Conditions for clearing the signal: 777 777 778 -* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 780 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time; 781 +* there is an error from "Errors 1, 2..." bitfields. 779 779 780 780 (% class="box infomessage" %) 781 781 ((( ... ... @@ -784,6 +784,7 @@ 784 784 785 785 === High voltage === 786 786 790 + 787 787 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 788 788 789 789 To change the parameters of high voltage fault, select the "Control → High voltage" section: