Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -319,12 +319,12 @@ 319 319 In **“Always on”** mode main contactor closes if all the following is true: 320 320 321 321 * Other contactors are open; 322 -* There are __no errors__from the "Errors 1, 2 ..." bitfileds.322 +* There are no errors from the "Errors 1, 2 ..." bitfileds. 323 323 324 324 and opens if all the following is true: 325 325 326 326 * Other contactors are open; 327 -* There is __an error__from the the "Errors 1, 2 ..." bitfileds.327 +* There is an error from the the "Errors 1, 2 ..." bitfileds. 328 328 329 329 In **“Automatic”** mode, the main contactor closes by internal algorithms at the same time with other contactors. 330 330 ... ... @@ -343,13 +343,13 @@ 343 343 344 344 * **Enable **– a flag to enable the main contactor control; 345 345 * **Algorithm** – main contactor control algorithm: 346 -** **Always on**– contactor is always closed;347 -** **Automatic**– contactor closes by internal charge and discharge algorithms;348 -** **On demand**– contactor is closed by an external request;349 -* **Time to keep the contactor closed before closing the others**– a time for other contactors to be open after the main contactor is closed;350 -* **Delay before opening the contactor**– a time which is used to detect conditions for opening the contactor, s;351 -* **Keep the contactor open until the device is restarted**– a flag for keeping the main contactor open until the system is reset;352 -* **Errors 1, 2 to open the main contactor**– bitfields to choose the errors which will open the main contactor.346 +** Always on – contactor is always closed; 347 +** Automatic – contactor closes by internal charge and discharge algorithms; 348 +** On demand – contactor is closed by an external request; 349 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 350 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 351 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 352 +* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 353 353 354 354 === Charging status === 355 355 ... ... @@ -359,17 +359,17 @@ 359 359 360 360 In this section: 361 361 362 -* **Current to set the "Charging current present"**– a current level to generate the "Charging current present" signal, A;363 -* **Current to clear the "Charging current present"**– a current level to clear the "Charging current present" signal, A;364 -* **Voltage to clear the “Ready to charge”**– a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;365 -* **Voltage to reset the “Ready to charge”**– a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set;366 -* **Use actual voltage to generate the "Ready to charge" signal**– a flag to disable voltage correction for "Ready to charge" signal;367 -* **Treat negative currents as zero currents for generating the "Ready to charge" signal**– a flag to disable voltage correction for "Ready to charge" signal at discharging current;368 -* **Delay before recharging**– a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;369 -* **Check the 'Charge current limit' value to generate the 'Ready to charge'**– a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;370 -* **Charge current limit to clear the 'Ready to charge'**– a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared;371 -* **Charge current limit to set the 'Ready to charge'**– a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set;372 -* **Errors 1, 2 to clear the "Ready to charge"**– bitfields to choose the errors which will clear the "Ready to charge" signal.362 +* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 363 +* Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 364 +* Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 365 +* Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 366 +* Use actual voltage to generate the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal; 367 +* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 368 +* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 369 +* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal; 370 +* Charge current limit to clear the 'Ready to charge' – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared; 371 +* Charge current limit to set the 'Ready to charge' – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set; 372 +* Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 373 373 374 374 (% class="box infomessage" %) 375 375 ((( ... ... @@ -386,15 +386,15 @@ 386 386 387 387 In this section: 388 388 389 -* **Current to set the "Discharging current present"**– a current level to generate the "Discharging current present" signal, А;390 -* **Current to clear the "Discharging current present"**– a current level to clear the "Discharging current present" signal, А;391 -* **Voltage to clear the “Ready to discharge”**– a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;392 -* **Voltage to reset the “Ready to discharge”**– a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;393 -* **Use actual voltage to generate the "Ready to discharge" signal**– a flag to disable voltage correction for "Ready to discharge" signal;394 -* **Treat positive currents as zero currents for generating the "Ready to discharge" signal**– a flag to disable voltage correction for "Ready to discharge" signal at charging current;395 -* **Check the 'Discharge current limit' value to generate the 'Ready to discharge'**– a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal;396 -* **Discharge current limit to clear the 'Ready to discharge'**– a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared;397 -* **Discharge current limit to set the 'Ready to discharge'**– a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set;389 +* Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 390 +* Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 391 +* Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 392 +* Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 393 +* Use actual voltage to generate the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal; 394 +* Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current; 395 +* Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 396 +* Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 397 +* Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 398 398 * Clear the 'Ready to discharge' signal if the 'Low SOC' signal is set; 399 399 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 400 400