Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -319,12 +319,12 @@ 319 319 In **“Always on”** mode main contactor closes if all the following is true: 320 320 321 321 * Other contactors are open; 322 -* There are __no errors__from the "Errors 1, 2 ..." bitfileds.322 +* There are no errors from the "Errors 1, 2 ..." bitfileds. 323 323 324 324 and opens if all the following is true: 325 325 326 326 * Other contactors are open; 327 -* There is __an error__from the the "Errors 1, 2 ..." bitfileds.327 +* There is an error from the the "Errors 1, 2 ..." bitfileds. 328 328 329 329 In **“Automatic”** mode, the main contactor closes by internal algorithms at the same time with other contactors. 330 330 ... ... @@ -343,13 +343,13 @@ 343 343 344 344 * **Enable **– a flag to enable the main contactor control; 345 345 * **Algorithm** – main contactor control algorithm: 346 -** **Always on**– contactor is always closed;347 -** **Automatic**– contactor closes by internal charge and discharge algorithms;348 -** **On demand**– contactor is closed by an external request;349 -* **Time to keep the contactor closed before closing the others**– a time for other contactors to be open after the main contactor is closed;350 -* **Delay before opening the contactor**– a time which is used to detect conditions for opening the contactor, s;351 -* **Keep the contactor open until the device is restarted**– a flag for keeping the main contactor open until the system is reset;352 -* **Errors 1, 2 to open the main contactor**– bitfields to choose the errors which will open the main contactor.346 +** Always on – contactor is always closed; 347 +** Automatic – contactor closes by internal charge and discharge algorithms; 348 +** On demand – contactor is closed by an external request; 349 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 350 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 351 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 352 +* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 353 353 354 354 === Charging status === 355 355 ... ... @@ -359,7 +359,7 @@ 359 359 360 360 In this section: 361 361 362 -* **Current to set the "Charging current present"**– a current level to generate the "Charging current present" signal, A;362 +* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 363 363 * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 364 364 * Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 365 365 * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set;