Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -319,12 +319,12 @@ 319 319 In **“Always on”** mode main contactor closes if all the following is true: 320 320 321 321 * Other contactors are open; 322 -* There are no errors from the "Errors 1, 2 ..." bitfileds. 322 +* There are __no errors__ from the "Errors 1, 2 ..." bitfileds. 323 323 324 324 and opens if all the following is true: 325 325 326 326 * Other contactors are open; 327 -* There is an error from the the "Errors 1, 2 ..." bitfileds. 327 +* There is __an error__ from the the "Errors 1, 2 ..." bitfileds. 328 328 329 329 In **“Automatic”** mode, the main contactor closes by internal algorithms at the same time with other contactors. 330 330 ... ... @@ -343,13 +343,13 @@ 343 343 344 344 * **Enable **– a flag to enable the main contactor control; 345 345 * **Algorithm** – main contactor control algorithm: 346 -** Always on – contactor is always closed; 347 -** Automatic – contactor closes by internal charge and discharge algorithms; 348 -** On demand – contactor is closed by an external request; 349 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 350 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 351 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 352 -* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 346 +** **Always on** – contactor is always closed; 347 +** **Automatic** – contactor closes by internal charge and discharge algorithms; 348 +** **On demand** – contactor is closed by an external request; 349 +* **Time to keep the contactor closed before closing the others** – a time for other contactors to be open after the main contactor is closed; 350 +* **Delay before opening the contactor** – a time which is used to detect conditions for opening the contactor, s; 351 +* **Keep the contactor open until the device is restarted** – a flag for keeping the main contactor open until the system is reset; 352 +* **Errors 1, 2 to open the main contactor** – bitfields to choose the errors which will open the main contactor. 353 353 354 354 === Charging status === 355 355 ... ... @@ -359,7 +359,7 @@ 359 359 360 360 In this section: 361 361 362 -* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 362 +* **Current to set the "Charging current present"** – a current level to generate the "Charging current present" signal, A; 363 363 * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 364 364 * Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 365 365 * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set;