... ... @@ -22,9 +22,9 @@
22 22  * **Parallel-Serial: Number of serial blocks in a string**;
23 23  * **Relax time (after charging)** – a relaxation time after charging, second;
24 24  * **Relax time (atfer discharging)** – a relaxation time after discharging, second;
25 -* **Reset SOC** – a command to reset cells state of charge. New cell SOC values will be calculated based on cell voltage and “Uocv (open-circuit voltage) table”: in the “Control → SOC estimation” section;
26 -* **Reset resistance** – a command to reset cells resistance to “Cell resistance” value;
27 -* **Reset capacity** – a command to reset cells capacity to “Cell capacity” value;
25 +* **Reset SOC** – a command to reset cells state of charge;
26 +* **Reset resistance** – a command to reset cells resistance;
27 +* **Reset capacity** – a command to reset cells capacity;
28 28  * **Method of calculating the battery voltage***:
29 29  ** **Summation of cell voltages** – the overall voltage is calculated as on sum of all cells in the battery;
30 30  ** **Using voltage before contactors** – the overall voltage is estimated as voltage before contactors measured by BMS.
... ... @@ -35,8 +35,14 @@
35 35  
36 36  The values of **“Relax time”** are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
37 37  
38 -The **“Reset ”** command is used for starting-up and adjustment of the battery.
38 +The** “Reset parameters”** will reset:
39 39  
40 +* state of charge (new cell SOC values will be calculated based on cell voltage and “Uocv (open-circuit voltage) table”: in the “Control → SOC estimation” section);
41 +* cell resistance to “Cell resistance” value;
42 +* battery capacity to “Cell capacity” value.
43 +
44 +The **“Reset parameters”** command is used for starting-up and adjustment of the battery.
45 +
40 40  === SOC estimation ===
41 41  