Page properties
Content
... ... @@ -12,31 +12,27 @@
12 12  
13 13  In this section:
14 14  
15 -* **Cell capacity** – nominal capacity of cells, Ah;
16 -* **Cell resistance** – nominal (maximum) internal resistance of the cells, Ohm;
17 -* **Connection of cells:**
18 -** **Serial **– all cells are connected in series in a single string.
19 -** **Parallel-Serial **– cells are grouped in parallel and serial items;
20 -* **Parallel-Serial: Number of Logic devices in a chain**;
21 -* **Parallel-Serial: Number of parallel chains in a block**;
22 -* **Parallel-Serial: Number of serial blocks in a string**;
23 -* **Relax time (after charging)** – a relaxation time after charging, second;
24 -* **Relax time (atfer discharging)** – a relaxation time after discharging, second;
25 -* **Reset SOC** – a command to reset cells state of charge. New cell SOC values will be calculated based on cell voltage and “Uocv (open-circuit voltage) table”: in the “Control → SOC estimation” section;
26 -* **Reset resistance** – a command to reset cells resistance to “Cell resistance” value;
27 -* **Reset capacity** – a command to reset cells capacity to “Cell capacity” value;
28 -* **Method of calculating the battery voltage***:
29 -** **Summation of cell voltages** – the overall voltage is calculated as on sum of all cells in the battery;
30 -** **Using voltage before contactors** – the overall voltage is estimated as voltage before contactors measured by BMS.
15 +* Cell capacity – nominal capacity of cells, Ah;
16 +* Cell resistance – nominal (maximum) internal resistance of the cells, Ohm;
17 +* Relax time (after charging) – a relaxation time after charging, second;
18 +* Relax time (atfer discharging) – a relaxation time after discharging, second;
19 +* Reset parameters – a command to reset cells state of charge, capacity, and resistance;
20 +* Method of calculating the battery voltage:
21 +** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery;
22 +** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS.
31 31  
32 -The **"Parallel-Serial"** connection works as follows: a bunch of serial connected Logics are grouped into chains. A bunch of parallel connected chains are grouped to blocks. A bunch of serial connected blocks are grouped into string. By configuring the corresponding settings it is possible to create a complex string configuration. Current through each chain will be estimated as a fraction of overall current accordingly to the number of chains in a block.
24 +The values “Capacity” and “Resistance are used to calculate the SOC of cells and the battery.
33 33  
34 -The values **Capacity** and **“Resistance”** are used to calculate the SOC of cells and the battery.
26 +The values of Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
35 35  
36 -The values of **“Relax time”** are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
28 +The “Reset parameters will reset:
37 37  
38 -The **“Reset ”** command is used for starting-up and adjustment of the battery.
30 +* state of charge (new cell SOC values will be calculated based on cell voltage and “Uocv (open-circuit voltage) table”: in the “Control → SOC estimation” section);
31 +* cell resistance to “Cell resistance” value;
32 +* battery capacity to “Cell capacity” value.
39 39  
34 +The “Reset parameters” command is used for starting-up and adjustment of the battery.
35 +
40 40  === SOC estimation ===
41 41  
42 42  The BMS Main 3 device calculates the state of charge of the battery (SOC) using two algorithms:
... ... @@ -381,7 +381,7 @@
381 381  
382 382  To change the parameters of charging process status, select the "Control → Charging status" section:
383 383  
384 -[[image:1771432488941-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="800"]]
380 +[[image:1760435790050-496.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="140" width="800"]]
385 385  
386 386  In this section:
387 387  
... ... @@ -389,7 +389,6 @@
389 389  * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A;
390 390  * Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;
391 391  * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set;
392 -* Use actual voltage to generate the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal;
393 393  * Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
394 394  * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
395 395  * Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;
... ... @@ -408,7 +408,7 @@
408 408  
409 409  To change the parameters of discharging process status, select the "Control → Discharging status" section:
410 410  
411 -[[image:1771431570393-551.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]]
406 +[[image:1760435802140-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
412 412  
413 413  In this section:
414 414  
... ... @@ -416,12 +416,10 @@
416 416  * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А;
417 417  * Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
418 418  * Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
419 -* Use actual voltage to generate the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal;
420 420  * Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current;
421 421  * Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal;
422 422  * Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared;
423 423  * Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set;
424 -* Clear the 'Ready to discharge' signal if the 'Low SOC' signal is set;
425 425  * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal.
426 426  
427 427  === Precharge ===