Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -648,7 +648,7 @@ 648 648 649 649 The BMS Main 3 / BMS Main 2R can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 650 650 651 -BMS Main 3 can force a cell balancing, if its voltage is higher than estimated value. 651 +BMS Main 3 / BMS Main 2R can force a cell balancing, if its voltage is higher than estimated value. 652 652 653 653 To change the cell balancing parameters, select the "Control → Cell balancing" section: 654 654 ... ... @@ -667,7 +667,7 @@ 667 667 * **Minimum cell voltage to start balancing**, V; 668 668 * **Voltage deviation to start balancing**; 669 669 * **Voltage deviation to stop balancing**; 670 -* **Voltage for forced balancing** – if cell voltage is above this value, it will start discharging through balancing resistor;670 +* **Voltage to start forced balancing** – if cell voltage is above this value, it will start discharging through balancing resistor; 671 671 * **Maximum allowable temperature of BMS Logic devices**, ºC; 672 672 * **Command to discharge all cells** – a flag to force the balancing of all cells. 673 673