Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -446,8 +446,12 @@ 446 446 447 447 There are two signals that serve charging the battery: "Charging" and "Allow charging". With the help of the "Allow charging" signal, the BMS commands the charger to start or stop charging. 448 448 449 - BMSMain3 / BMS Main 2Rsupports three charge control algorithms:449 +The device supports three charge control algorithms: 450 450 451 +* Always on – charging is always allowed; 452 +* On charger connected – charging is allowed when there is a signal “Charger connected”; 453 +* On charge request – charging is allowed when there is a signal “Charge request”. 454 + 451 451 If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 452 452 453 453 * Service reset; ... ... @@ -459,12 +459,16 @@ 459 459 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 460 460 461 461 * If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 462 -* If the signal “Charger connected” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens. 466 +* If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 467 +* If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 468 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 463 463 464 464 When the "**On charge request**" algorithm selected, the control is performed as follows: 465 465 466 466 * If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 467 -* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 473 +* If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 474 +* If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 475 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 468 468 469 469 (% class="box infomessage" %) 470 470 ((( ... ... @@ -477,26 +477,30 @@ 477 477 478 478 In this section: 479 479 480 -* **Enable**– a flag to activate the charge control;481 -* **Algorithm**:482 -** **Always on**– charging is always allowed;483 -** **On charger connected**– charging is allowed when there is a signal “Charger connected”;484 -** **On charge request**– charging is allowed when there is a signal “Charge request”;485 -* **Allow charging only when the "Ready to charge" signal is set**– charging contactor will open if "Ready to charge" signal is cleared;486 -* **Delay before starting charging**– a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;487 -* **Delay before stopping charging**– a time delay T,,off,, before opening the charging contactor, millisecond;488 -* **Control the precharging contactor**– a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);489 -* **Errors 1, 2 to open the charging contactor**– bitfields to choose the errors which will open the charging contactor;490 -* **Use custom delays before stopping charging (on errors)**– a flag to enable manual settings of time delays T,,off,, for specific errors;491 -* **Custom delay: <error>**– delay for specific error, millisecond;492 -* **Switch off the charging contactor on errors without delay**– a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”;488 +* Enable – a flag to activate the charge control; 489 +* Algorithm: 490 +** Always on – charging is always allowed; 491 +** On charger connected – charging is allowed when there is a signal “Charger connected”; 492 +** On charge request – charging is allowed when there is a signal “Charge request”; 493 +* Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 494 +* Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 495 +* Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 496 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]); 497 +* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 498 +* Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 499 +* Custom delay: <error> – delay for specific error, millisecond; 500 +* Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 493 493 494 494 === Discharge === 495 495 496 -The BMS Main 3 / BMS Main 2Rdevice controls the discharging contactor to connect battery to the load.504 +The device controls the discharging contactor to connect battery to the load. 497 497 498 - BMSMain3 / BMS Main 2Rsupports three algorithms to control battery discharging:506 +The device supports three algorithms to control battery discharging: 499 499 508 +* Always on – load is always connected; 509 +* On charger disconnected – load is connected when there is no signal “Charger connected”; 510 +* On discharge request – load is connected when there is signal “Discharge request”. 511 + 500 500 When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 501 501 502 502 * Service reset ... ... @@ -526,46 +526,32 @@ 526 526 527 527 In this section: 528 528 529 -* **Enable**– a flag to activate the discharge control;530 -* **Algorithm**:531 -** **Always on**– load is always connected;532 -** **On charger disconnected**– load is connected when there is no signal “Charger connected”;533 -** **On discharge request**– load is connected when there is signal “Discharge request”;534 -* **Allow charging only when the "Ready to discharge" signal is set**– discharging contactor will open if "Ready to discharge" signal is cleared;535 -* **Delay before starting discharging**– a time delay T,,on,, before closing the discharging contactor, millisecond;536 -* **Delay before stopping discharging**– a time delay T,,off,, before opening the discharging contactor, millisecond;537 -* **Control the precharging contactor**– a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]);538 -* **Errors 1, 2 to open the discharging contactor**– bitfields to choose the errors which will open the discharging contactor;539 -* **Use custom delays before stopping discharging (on errors)**– a flag to enable manual settings of time delays T,,off,, for specific errors;540 -* **Custom delay: <error>**– specific error delay, millisecond;541 -* **Switch off the discharging contactor on errors without delay**– a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”.541 +* Enable – a flag to activate the discharge control; 542 +* Algorithm: 543 +** Always on – load is always connected; 544 +** On charger disconnected – load is connected when there is no signal “Charger connected”; 545 +** On discharge request – load is connected when there is signal “Discharge request”; 546 +* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 547 +* Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 548 +* Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 549 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]); 550 +* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 551 +* Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 552 +* Custom delay: <error> – specific error delay, millisecond; 553 +* Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 542 542 543 543 === Charge/Discharge === 544 544 545 -The BMS Main 3 / BMS Main 2Rdevice can control theCharge/Discharge contactor, which combines algorithms of charging and discharging contactor.557 +The BMS Main 3 device can control the charge/discharge contactor, which combines algorithms of charging and discharging contactor. 546 546 547 547 Charge/Discharge contactor has three algorithms of operation: 548 548 549 -On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge algorithms and their signals and behaves 561 +* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 562 +* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 563 +* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs. 550 550 551 -* as Charging contactor if "Charging" signal is set; 552 -* as Discharging contactor in other cases. 565 +TBA 553 553 554 -When **Independent (Always) **algorithm is selected, the charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 555 - 556 -* Service reset 557 -* Power down request 558 -* Inhibit charging 559 -* Inhibit discharging 560 - 561 -the charging/discharging contactor opens. 562 - 563 - 564 -**Independent (on Charge request or Discharge request)** - charge/discharge contactor is based on its own controller and performs as follows: 565 - 566 -* if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging/discharging contactor closes; 567 -* If the "Charge request" or "Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the charging/discharging contactor opens. 568 - 569 569 (% class="box infomessage" %) 570 570 ((( 571 571 **Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). ... ... @@ -577,23 +577,23 @@ 577 577 578 578 In this section: 579 579 580 -* **Enable**– a flag to enable the charge/discharge controller.581 -* **Algorithm**:582 -** **Dependent (on Charging and Discharging signals)**- Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor;583 -** **Independent (Always)**- Charge/Discharge contactor is always closed if there is no errors;584 -** **Independent (on Charge request or Discharge request)**;585 -* **Delay before starting charging or discharging**, millisecond;586 -* **Delay before stopping charging or discharging**, millisecond;587 -* **Control the precharging contactor**– a flag that enables control of precharging contactor while closing the charge/discharge contactor;588 -* **Emulate the "Charging" and "Discharging" signals**– a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor;589 -* **Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor**– bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes;590 -* **Errors 1, 2 which affect the contactor only if battery CHARGING is detected**– a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND;591 -* **Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected**– a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND;592 -* **Switch off the charging/discharging contactor on errors without delay**– a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”.578 +* Enable – a flag to enable the charge/discharge controller. 579 +* Algorithm: 580 +** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 581 +** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 582 +** Independent (on Charge request or Discharge request); 583 +* Delay before starting charging or discharging, millisecond; 584 +* Delay before stopping charging or discharging, millisecond; 585 +* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 586 +* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 587 +* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 588 +* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 589 +* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; 590 +* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”. 593 593 594 594 === Discharge (AUX) === 595 595 596 -The BMS Main 3 / BMS Main 2Rdevice can control the power supply of external equipment using the auxiliary (AUX) discharging contactor. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices.594 +The BMS Main 3 device can control the power supply of external equipment using the auxiliary (AUX) discharging contactor. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices. 597 597 598 598 The power supply circuit of the external equipment using the auxiliary (AUX) discharging contactor is independent of the battery load circuit. The closing and opening of the auxiliary (AUX) discharging contactor is performed according to its program. 599 599 ... ... @@ -609,17 +609,17 @@ 609 609 610 610 In this section: 611 611 612 -* **Enable**– a flag to activate the auxiliary discharge control;613 -* **Switch off the discharging (AUX) contactor if the SOC is too low**;614 -* **Minimum SOC**– a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %;615 -* **Tolerant SOC**– a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %;616 -* **Switch off the discharging (AUX) contactor if the cell voltage is out of the range**;617 -* **Minimum cell voltage**, V;618 -* **Maximum cell voltage**, V;619 -* **Switch off the discharging (AUX) contactor if the battery voltage is out of the range**;620 -* **Minimum battery voltage**, V;621 -* **Maximum battery voltage**, V;622 -* **Errors 1, 2 to open the auxiliary discharging contactor**– bitfields to choose the errors which will open the auxiliary discharging contactor.610 +* Enable – a flag to activate the auxiliary discharge control; 611 +* Switch off the discharging (AUX) contactor if the SOC is too low; 612 +* Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 613 +* Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 614 +* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 615 +* Minimum cell voltage, V; 616 +* Maximum cell voltage, V; 617 +* Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 618 +* Minimum battery voltage, V; 619 +* Maximum battery voltage, V; 620 +* Errors 1, 2 to open the auxiliary discharging contactor – bitfields to choose the errors which will open the auxiliary discharging contactor. 623 623 624 624 === Cell balancing === 625 625 ... ... @@ -656,7 +656,7 @@ 656 656 657 657 In this section: 658 658 659 -* **Enable**– a flag to enable cell balancing;657 +* Enable – a flag to enable cell balancing; 660 660 * Balancing rule: 661 661 ** Balance on charge – balancing is performed while and after the charging (in the “Charge ON” and “Charge OFF” states); 662 662 ** Balance on charge or relaxed - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states);