... ... @@ -444,7 +444,7 @@
444 444  
445 445  === Charge ===
446 446  
447 -There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging.
447 +There are two signals that serve charging the battery: "Charging" and "Allow charging". With the help of the "Allow charging" signal, the BMS commands the charger to start or stop charging.
448 448  
449 449  The device supports three charge control algorithms:
450 450