Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -402,12 +402,10 @@ 402 402 403 403 The BMS Main 3 / BMS Main 2R device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor. 404 404 405 - In**simple**mode precharge contactorclosesafbeforethe closingChargeof Discharge contactors405 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. 406 406 407 -BMS Main 3candetect errors while pre-charging the load capacity by monitoring the currentand voltage difference before and after contactors.407 +BMS Main 2R device detects errors while pre-charging the load capacity only by monitoring the current. 408 408 409 -BMS Main 2R can detect errors while pre-charging the load capacity __only__ by monitoring the current. 410 - 411 411 Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit. 412 412 413 413 TBA