Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -106,23 +106,13 @@ 106 106 107 107 The BMS Main 3 device calculates the state of health of the battery (SOH) using two algorithms: 108 108 109 -* By effective capacity;110 -* By total charge-.109 +* by effective capacity; 110 +* by total charge-. 111 111 112 -In "By effective capacity" mode SOH is calculated as a ratio of effective capacity to nominal capacity. Effective capacity is estimated to DOD value when battery SOC reaches 0%, so SOH is recalculated each full battery discharge.112 +In "By effective capacity" mode SOH is calculated as a ratio of effective capacity to nominal capacity. 113 113 114 -In "By total charge-" mode SOH is calculated as a linear function of "Total charge-" counter. While "Total charge-" constantly increases during battery operation, SOH will be linearly decrease at the same time. This mode requires a confirmed data about cell health depending of amount of discharge rate to configure the linear function.114 +In "By total charge-" mode SOH is calculated as a 115 115 116 -To configure parameters for battery state of health calculation, select the "Control → SOH correction" section: 117 - 118 -[[image:1765447975228-766.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]In this section: 119 - 120 -* Algorithm: 121 -** By effective capacity; 122 -** By total charge-; 123 -* Total charge: Charge- – total amount of charge- for expected SOH; 124 -* Total charge: SOH – expected SOH value at the total amount of charge-. 125 - 126 126 === Resistance estimation === 127 127 128 128 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value ... ... @@ -403,7 +403,7 @@ 403 403 404 404 To change the parameters of discharging process status, select the "Control → Discharging status" section: 405 405 406 -[[image:17 71431570393-551.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]]396 +[[image:1760435802140-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 407 407 408 408 In this section: 409 409 ... ... @@ -415,7 +415,6 @@ 415 415 * Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 416 416 * Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 417 417 * Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 418 -* Clear the 'Ready to discharge' signal if the 'Low SOC' signal is set; 419 419 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 420 420 421 421 === Precharge ===
- 1765447975228-766.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.8 KB - Content
- 1765448283865-334.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.9 KB - Content
- 1771431551882-439.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.7 KB - Content
- 1771431570393-551.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.7 KB - Content