- Content
-
... ... @@ -12,47 +12,35 @@ 12 12 13 13 In this section: 14 14 15 -* Cell capacity – nominal capacity of cells, Ah; 16 -* Cell resistance – nominal (maximum) internal resistance of the cells, Ohm; 17 -* Relax time (after charging) – a relaxation time after charging, second; 18 -* Relax time (atfer discharging) – a relaxation time after discharging, second; 19 -* Reset parameters – a command to reset cells state of charge, capacity, and resistance; 20 -* Method of calculating the battery voltage: 21 -** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery; 22 -** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS. 15 +* **Cell capacity** – nominal capacity of cells, Ah; 16 +* **Cell resistance** – nominal (maximum) internal resistance of the cells, Ohm; 17 +* **Connection of cells:** 18 +** **Serial **– all cells are connected in series in a single string; 19 +** **Parallel-Serial **– cells are grouped in parallel and serial items; 20 +* **Parallel-Serial: Number of Logic devices in a chain**; 21 +* **Parallel-Serial: Number of parallel chains in a block**; 22 +* **Parallel-Serial: Number of serial blocks in a string**; 23 +* **Relax time (after charging)** – a relaxation time after charging, second; 24 +* **Relax time (atfer discharging)** – a relaxation time after discharging, second; 25 +* **Reset SOC** – a command to reset cells state of charge. New cell SOC values will be calculated based on cell voltage and “Uocv (open-circuit voltage) table”: in the “Control → SOC estimation” section; 26 +* **Reset resistance** – a command to reset cells resistance to “Cell resistance” value; 27 +* **Reset capacity** – a command to reset cells capacity to “Cell capacity” value; 28 +* **Method of calculating the battery voltage***: 29 +** **Summation of cell voltages** – the overall voltage is calculated as on sum of all cells in the battery; 30 +** **Using voltage before contactors** – the overall voltage is estimated as voltage before contactors measured by BMS. 23 23 24 -The values“Capacity”and“Resistance”are used to calculate theSOCofcells andthe battery.32 +The **"Parallel-Serial"** connection works as follows: a bunch of serial connected Logics are grouped into chains. A bunch of parallel connected chains are grouped to blocks. A bunch of serial connected blocks are grouped into string. By configuring the corresponding settings it is possible to create a complex string configuration. Current through each chain will be calculated as overall string current divided by number of chains in a block. 25 25 26 -The values of“Relax time” are usedto determine thestateof the battery. If thebattery isin a stateof relaxation,the system recalculatesthevoltageonthecellsto the stateof charge ofthe battery.34 +The values **“Capacity”** and **“Resistance”** are used to calculate the SOC of cells and the battery. 27 27 28 -The “Reset parameters”willreset:36 +The values of **“Relax time”** are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. 29 29 30 -* state of charge (new cell SOC values will be calculated based on cell voltage and “Uocv (open-circuit voltage) table”: in the “Control → SOC estimation” section); 31 -* cell resistance to “Cell resistance” value; 32 -* battery capacity to “Cell capacity” value. 38 +The **“Reset SOC”, "Reset resistance" **and **"Reset capacity"** command is used for starting-up and adjustment of the battery. 33 33 34 -The “Reset parameters” command is used for starting-up and adjustment of the battery. 35 - 36 36 === SOC estimation === 37 37 38 -The BMS Main 3 device calculates the state of charge of the battery(SOC)usingtwo algorithms:42 +The BMS Main 3 / BMS Main 2R device calculates the state of charge (SOC) of each cell by using following algorithms: 39 39 40 -* by open circuit voltage; 41 -* by voltage and current. 42 - 43 -It is recommended to use the algorithm of calculation of SOC by voltage and current. 44 - 45 -To change the estimation algorithm for calculating the battery SOC, select the "Control → SOC estimation → Algorithm" section: 46 - 47 - 48 -[[image:1735056107942-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] 49 - 50 -The following estimation algorithms supported: 51 - 52 -* Voltage – by open circuit voltage; 53 -* Current and voltage (simplified) – recommended for LFP cells; 54 -* Current and voltage (enhanced) – recommended for NMC cells. 55 - 56 56 The **“Voltage”** SOC calculation algorithm calculates cells SOC based on the tabular dependence Uocv = Uocv(SOC, t °C). 57 57 58 58 The **“Current and voltage (simplified)”** SOC calculation algorithm works as follows: ... ... @@ -62,32 +62,34 @@ 62 62 63 63 The **“Current and voltage (enhanced)” **SOC calculation algorithm differs from the simplified algorithm by online correction of the effective capacity. When using this algorithm, it is necessary to fine tune the tabular dependence Uocv = Uocv (SOC, t °C). 64 64 65 -To change the algorithm for calculating the FinalSOC, select the "Control → SOC estimation→ Final SOC" section:53 +To change the algorithm for calculating the SOC, select the "Control → SOC estimation" section: 66 66 67 67 [[image:1733322611551-852.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 68 68 69 - The followingcalculation methodsaresupported (“Final SOC”):57 +In this section: 70 70 71 -* Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells; 72 -* Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC; 73 -* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC; 74 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC. 59 +* **Algorithm:** 60 +** **Voltage **– by open circuit voltage; 61 +** **Current and voltage (simplified)** – recommended for LFP cells; 62 +** **Current and voltage (enhanced)** – recommended for NMC cells: 63 +* **Final SOC** – method of calculating overall SOC of battery: 64 +** **Minimal SOC** – the battery SOC is assumed to be the minimum SOC among the cells; 65 +** **Average SOC** – the battery SOC is taken equal to the arithmetic average of the cell SOC; 66 +** **Min-Max SOC** – the battery SOC is calculated based on the minimum and maximum SOC of the cells (recommended). Final SOC will be a) 100% if __any cell__ has 100% SOC, b) 0% if __any cell__ has 0% SOC; 67 +** **Max-Min SOC** – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if __all cells__ have 100% SOC, b) 0% if __all// //cells__ have 0% SOC. 68 +* **Scale the final SOC** – a flag to scale the battery SOC by the following values; 69 +* **SOC corresponding to 0%** – the battery SOC that sets to be 0%; 70 +* **SOC corresponding to 100%** – the battery SOC that sets to be 100%. 71 +* **Uocv (open-circuit voltage) table** – the dependence of the cell open circuit voltage Uocv on SOC and the cell temperature (selected for specific batteries); 72 +* **Linear zone** - linear zone of the Uocv = Uocv(SOC, t°C) dependency, inside which the cell voltage changes insignificantly: 73 +** **Linear zone: point 1** – starting point of the Uocv linear zone; 74 +** **Linear zone: point 2** – ending point of the Uocv linear zone; 75 +* **Coulomb counting correction (temperature)** – the dependence of battery capacity on temperature; 76 +* **Coulomb counting correction (cycles)** – the dependence of battery capacity on the number of charge-discharge cycles. 75 75 76 -Other parameters: 77 - 78 -* Scale the final SOC – a flag to scale the battery SOC by the following values; 79 -* SOC corresponding to 0% – the battery SOC that sets to be 0%; 80 -* SOC corresponding to 100% – the battery SOC that sets to be 100%. 81 -* Uocv (open-circuit voltage) table – the dependence of the cell open circuit voltage Uocv on SOC and the cell temperature (selected for specific batteries); 82 -* Linear zone - linear zone of the Uocv = Uocv(SOC, t°C) dependency, inside which the cell voltage changes insignificantly: 83 -** Linear zone: point 1 – starting point of the Uocv linear zone; 84 -** Linear zone: point 2 – ending point of the Uocv linear zone; 85 -* Coulomb counting correction (temperature) – the dependence of battery capacity on temperature; 86 -* Coulomb counting correction (cycles) – the dependence of battery capacity on the number of charge-discharge cycles. 87 - 88 88 === SOC correction === 89 89 90 -The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[SOC estimation>>doc:||anchor="HSOCestimation"]]). 80 +The BMS Main 3 / BMS Main 2R device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[SOC estimation>>doc:||anchor="HSOCestimation"]]). 91 91 92 92 To configure parameters for periodically correcting the battery state of charge, select the "Control → SOC correction" section: 93 93 ... ... @@ -95,22 +95,31 @@ 95 95 96 96 In this section: 97 97 98 -* Enable – a flag to enable the SOC correction; 99 -* Shutdown period – a time the battery is off, day. If the BMS detects on its startup that it was off during the “Shutdown period” time, the BMS recalculates the battery state of charge based on the tabular dependency Uocv = Uocv (SOC, t); 100 -* Correction period – a period of correcting the battery SOC, day. If the BMS detects that the last correction was more than the “Correction period” ago, the BMS recalculates the battery state of charge based on the tabular dependency Uocv = Uocv (SOC, t) and tunes it gradually during the “SOC change time”. 101 -* SOC change time – a duration of the linear changing the battery SOC to the value calculated by the correction algorithm, minute; 102 -* Ignore the linear zone – a flag to ignore linear SOC zone while correction (recommended to be unset); 103 -* Last correction timestamp – time when last correction was made. 88 +* **Enable **– a flag to enable the SOC correction; 89 +* **Shutdown period** – a time the battery is off, day. If the BMS detects on its startup that it was off during the “Shutdown period” time, the BMS recalculates the battery state of charge based on the tabular dependency Uocv = Uocv (SOC, t); 90 +* **Correction period** – a period of correcting the battery SOC, day. If the BMS detects that the last correction was more than the “Correction period” ago, the BMS recalculates the battery state of charge based on the tabular dependency Uocv = Uocv (SOC, t) and tunes it gradually during the “SOC change time”. 91 +* **SOC change time** – a duration of the linear changing the battery SOC to the value calculated by the correction algorithm, minute; 92 +* **Ignore the linear zone** – a flag to ignore linear SOC zone while correction (recommended to be unset); 93 +* **Last correction timestamp** – time when last correction was made. 104 104 105 105 === SOH estimation === 106 106 107 -The BMS Main 3 device calculates the state of health of the battery (SOH) using two algorithms: 97 +The BMS Main 3 / BMS Main 2R device calculates the state of health of the battery (SOH) using two algorithms: 108 108 109 -* by effective capacity; 110 -* by total charge-. 99 +In **"By effective capacity" **mode SOH is calculated as a ratio of effective capacity to nominal capacity. Effective capacity is estimated to DOD value when battery SOC reaches 0%, so SOH is recalculated each full battery discharge. 111 111 112 -In "By effective capacity"mode SOH iscalculated as101 +In** "By total charge–"** mode SOH is calculated as a linear function of "Total charge-" counter. While "Total charge-" constantly increases during battery operation, SOH will be linearly decrease at the same time. This mode requires a confirmed data about cell health depending of amount of discharge rate to configure the linear function. 113 113 103 +To configure parameters for battery state of health calculation, select the "Control → SOH correction" section: 104 + 105 +[[image:1765447975228-766.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]In this section: 106 + 107 +* **Algorithm:** 108 +** **By effective capacity;** 109 +** **By total charge–;** 110 +* **Total charge: Charge–** – total amount of charge– for expected SOH; 111 +* **Total charge: SOH** – expected SOH value at the total amount of charge–. 112 + 114 114 === Resistance estimation === 115 115 116 116 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value ... ... @@ -143,16 +143,18 @@ 143 143 144 144 In this section: 145 145 146 -* Current stabilization time, millisecond; 147 -* Maximum calculation period – maximum time between resistance measurements. If more time has elapsed since the last determination of the stabilized current I,,stable,, than is determined in this field, the resistance calculation is not performed, second; 148 -* Maximum resistance factor – the coefficient of calculation of the maximum acceptable resistance of the cell; 149 -* Minimum SOC – minimum cell SOC value for resistance calculation; 150 -* Maximum SOC – maximum cell SOC value for resistance calculation. 145 +* **Current stabilization time**, millisecond; 146 +* **Maximum calculation period** – maximum time between resistance measurements. If more time has elapsed since the last determination of the stabilized current I,,stable,, than is determined in this field, the resistance calculation is not performed, second; 147 +* **Maximum resistance factor** – the coefficient of calculation of the maximum acceptable resistance of the cell; 148 +* **Minimum SOC** – minimum cell SOC value for resistance calculation; 149 +* **Maximum SOC** – maximum cell SOC value for resistance calculation. 151 151 152 152 The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance / 2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 153 153 154 154 === Low SOC (signal) === 155 155 155 +The "Low SOC" is indicative signal that can be assigned to a discrete output or a power switch. 156 + 156 156 To change the parameters of the generation a signal about low battery level, select the "Control → Low SOC (signal)" section: 157 157 158 158 [[image:1733322624660-513.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] ... ... @@ -159,12 +159,12 @@ 159 159 160 160 In this section: 161 161 162 -* Enable – a flag to enable signal generation; 163 -* Minimum SOC, %; 164 -* Tolerant SOC, %; 165 -* Delay before setting the signal, second; 166 -* Delay before clearing the signal, second; 167 -* Lock – lock the signal until the device is reset. 163 +* **Enable **– a flag to enable signal generation; 164 +* **Minimum SOC**, %; 165 +* **Tolerant SOC**, %; 166 +* **Delay before setting the signal**, second; 167 +* **Delay before clearing the signal**, second; 168 +* **Lock** – lock the signal until the device is reset. 168 168 169 169 Signal generation conditions: 170 170 ... ... @@ -174,13 +174,10 @@ 174 174 175 175 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 176 176 177 -(% class="box infomessage" %) 178 -((( 179 -The "Low SOC signal" is indicative and can be output to a discrete output or a power switch. 180 -))) 181 - 182 182 === High charging current (signal) === 183 183 180 +The "High charging current" is indicative signal that can be output to a discrete output or a power switch. 181 + 184 184 To change the parameters of the generation high-current signal, select the "Control → High charging current (signal)" section: 185 185 186 186 [[image:1733322624661-915.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]] ... ... @@ -187,12 +187,12 @@ 187 187 188 188 In this section: 189 189 190 -* Enable – a flag to enable signal generation;191 -* Maximum charging current, А; 192 -* Tolerant charging current, А; 193 -* Delay before setting the signal, second; 194 -* Delay before clearing the signal, second; 195 -* Lock – lock the signal until the device is reset. 188 +* **Enable **– a flag to enable signal generation; 189 +* **Maximum charging current**, А; 190 +* **Tolerant charging current**, А; 191 +* **Delay before setting the signal**, second; 192 +* **Delay before clearing the signal**, second; 193 +* **Lock **– lock the signal until the device is reset. 196 196 197 197 Signal generation conditions: 198 198 ... ... @@ -202,14 +202,9 @@ 202 202 203 203 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 204 204 205 -(% class="box infomessage" %) 206 -((( 207 -The "High charging current" signal is indicative and can be output to a discrete output or a power switch. 208 -))) 209 - 210 210 === Charge map === 211 211 212 -The BMS Main 3 device calculates the maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 205 +The BMS Main 3 / BMS Main 2R device calculates the maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 213 213 214 214 Calculated current values are sent to a charger or an intellectual load over the CAN bus. External devices based on received data provide correct battery operation. 215 215 ... ... @@ -219,17 +219,17 @@ 219 219 220 220 In this section: 221 221 222 -* Enable – a flag to start calculation of the charge current limit; 223 -* Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A; 224 -* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 225 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on __maximum cell SOC__ and battery temperature; 226 -* Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 227 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 228 -* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 229 -* Option 3: Limit charge current by the maximum cell voltage -a flag to enable correction of maximum allowable charging current **Kcv** depending on __the maximum cell U,,ocv,, voltage__ (corrected due to current and cell resistance)230 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage; 231 -* Option 4: Limit charge current by the cell temperature -a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature;232 -* Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature. 215 +* **Enable **– a flag to start calculation of the charge current limit; 216 +* **Maximum charge current** – a maximum allowable value of the charge current (under normal conditions), A; 217 +* **Rate of change** – a rate of change the current limit to a new value (0 is for immediate change), A/s; 218 +* **Option 1: Limit charge current by the battery SOC and temperature** – a flag to enable correction of maximum allowable charging current** Kcs** depending on __maximum cell SOC__ and battery temperature; 219 +* **Option 1: SOC x Temperature x Factor** – the dependence of the correction factor on SOC and battery temperature; 220 +* **Option 2: Limit charge current by the contactor temperature** – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 221 +* **Option 2: Contactor temperature x Factor** – the dependence of the correction factor on SOC and contactor temperature; 222 +* **Option 3: Limit charge current by the maximum cell voltage** – a flag to enable correction of maximum allowable charging current **Kcv** depending on __the maximum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 223 +* **Option 3: Cell voltage x Factor** – the dependence of the correction factor on maximum cell voltage; 224 +* **Option 4: Limit charge current by the cell temperature** – a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 225 +* **Option 4: Cell temperature x Factor** – the dependence of the correction factor on maximum cell temperature. 233 233 234 234 Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows: 235 235 ... ... @@ -237,7 +237,7 @@ 237 237 238 238 === Discharge map === 239 239 240 -The BMS Main 3 device calculates the maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 233 +The BMS Main 3 / BMS Main 2R device calculates the maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 241 241 242 242 Calculated current values are sent to a charger or an intellectual load over the CAN bus. 243 243 ... ... @@ -247,17 +247,17 @@ 247 247 248 248 In this section: 249 249 250 -* Enable – a flag to start calculation of the discharge current limit; 251 -* Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 252 -* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 253 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on __minimum cell SOC__ and temperature; 254 -* Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 255 -* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 256 -* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 257 -* Option 3: Limit discharge current by the cell voltage -a flag to enable correction of maximum allowable discharging current **Kdv** depending on __the minimum cell U,,ocv,, voltage__ (corrected due to current and cell resistance)258 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 259 -* Option 4: Limit discharge current by the cell temperature -a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature;260 -* Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. 243 +* **Enable **– a flag to start calculation of the discharge current limit; 244 +* **Maximum discharge current** – a maximum allowable value of the discharge current (under normal conditions), A; 245 +* **Rate of change** – a rate of change the current limit to a new value (0 is for immediate change), A/s; 246 +* **Option 1: Limit discharging current by the battery SOC and temperature** – a flag to enable correction of maximum allowable discharging current **Kds **depending on __minimum cell SOC__ and temperature; 247 +* **Option 1: SOC x Temperature x Factor** – the dependence of the correction factor on SOC and battery temperature; 248 +* **Option 2: Limit discharge current by the contactor temperature** – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 249 +* **Option 2: Contactor temperature x Factor** – the dependence of the correction factor on SOC and contactor temperature; 250 +* **Option 3: Limit discharge current by the cell voltage** – a flag to enable correction of maximum allowable discharging current **Kdv** depending on __the minimum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 251 +* **Option 3: Cell voltage x Factor** – the dependence of the correction factor on minimum cell voltage; 252 +* **Option 4: Limit discharge current by the cell temperature** – a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 253 +* **Option 4: Cell voltage x Factor** – the dependence of the correction factor on minimum cell temperature. 261 261 262 262 Value of the discharge current limit at given SOC, temperature, contactors temperature, minimum cell voltage and maximum cell temperature is calculated as follows: 263 263 ... ... @@ -265,7 +265,7 @@ 265 265 266 266 === Charge map (PEAK & CONTINUOUS) === 267 267 268 -The BMS Main 3 has an alternative algorithm for the maximum allowed charging current based on peak and continuous battery operating modes. 261 +The BMS Main 3 / BMS Main 2R has an alternative algorithm for the maximum allowed charging current based on peak and continuous battery operating modes. 269 269 270 270 To configure parameters for determining the charge current limit, select the "Control → Charge map (PEAK & CONTINUOUS)" section: 271 271 ... ... @@ -273,26 +273,26 @@ 273 273 274 274 In this section: 275 275 276 -* Enable – a flag to start calculation of the charge current limit; 277 -* Maximum PEAK charge current – a maximum peak charge current (under normal conditions), A; 278 -* Maximum CONTINUOUS charge current – a maximum continuous charge current (under normal conditions), A; 279 -* PEAK: SOC x Temperature x Factor – the dependence of the correction factor for peak current K,,cp,, on SOC and battery temperature; 280 -* CONTINUOUS: SOC x Temperature x Factor – the dependence of the correction factor for continuous current K,,cc,, on SOC and battery temperature; 281 -* PEAK time – a time for peak current to be allowed, s; 282 -* Sliding time – a time of linear change of the maximum charging current from peak to continuous and from continuous to peak value, ms; 283 -* Waiting time – a time for peak current to be prohibited, s. 269 +* **Enable **– a flag to start calculation of the charge current limit; 270 +* **Maximum PEAK charge current** – a maximum peak charge current (under normal conditions), A; 271 +* **Maximum CONTINUOUS charge current** – a maximum continuous charge current (under normal conditions), A; 272 +* **PEAK: SOC x Temperature x Factor** – the dependence of the correction factor for peak current K,,cp,, on SOC and battery temperature; 273 +* **CONTINUOUS: SOC x Temperature x Factor** – the dependence of the correction factor for continuous current K,,cc,, on SOC and battery temperature; 274 +* **PEAK time** – a time for peak current to be allowed, s; 275 +* **Sliding time** – a time of linear change of the maximum charging current from peak to continuous and from continuous to peak value, ms; 276 +* **Waiting time** – a time for peak current to be prohibited, s. 284 284 285 285 The maximum charging current value equals to the peak or continuous current according to the following diagram: 286 286 287 287 [[image:1733322717451-608.png||data-xwiki-image-style-alignment="center"]] 288 288 289 -I,,peak,, = Maximum PEAK charge current × K,,cp,, 282 +**I,,peak,, = Maximum PEAK charge current × K,,cp,,** 290 290 291 -I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,, 284 +**I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,,** 292 292 293 293 === Discharge map (PEAK & CONTINUOUS) === 294 294 295 -The BMS Main 3 has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes. 288 +The BMS Main 3 / BMS Main 2R has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes. 296 296 297 297 To configure parameters for determining the discharge current limit, select the "Control → Discharge map (PEAK & CONTINUOUS)" section: 298 298 ... ... @@ -300,45 +300,42 @@ 300 300 301 301 In this section: 302 302 303 -* Enable – a flag to start calculation of the discharge current limit; 304 -* Maximum PEAK discharge current – a maximum peak discharge current (under normal conditions), A; 305 -* Maximum CONTINUOUS discharge current – a maximum continuous discharge current (under normal conditions), A; 306 -* PEAK: SOC x Temperature x Factor – the dependence of the correction factor for peak current K,,dp,, on SOC and battery temperature; 307 -* CONTINUOUS: SOC x Temperature x Factor – the dependence of the correction factor for continuous current K,,dc,, on SOC and battery temperature; 308 -* PEAK time – a time for peak current to be allowed, s; 309 -* Sliding time – a time of linear change of the maximum charging current from peak to continuous and from continuous to peak value, ms; 310 -* Waiting time – a time for peak current to be prohibited, s. 296 +* **Enable **– a flag to start calculation of the discharge current limit; 297 +* **Maximum PEAK discharge current** – a maximum peak discharge current (under normal conditions), A; 298 +* **Maximum CONTINUOUS discharge current** – a maximum continuous discharge current (under normal conditions), A; 299 +* **PEAK: SOC x Temperature x Factor** – the dependence of the correction factor for peak current K,,dp,, on SOC and battery temperature; 300 +* **CONTINUOUS: SOC x Temperature x Factor** – the dependence of the correction factor for continuous current K,,dc,, on SOC and battery temperature; 301 +* **PEAK time** – a time for peak current to be allowed, s; 302 +* **Sliding time** – a time of linear change of the maximum charging current from peak to continuous and from continuous to peak value, ms; 303 +* **Waiting time** – a time for peak current to be prohibited, s. 311 311 312 312 The maximum discharging current value equals to the peak or continuous current according to following diagram: 313 313 314 314 [[image:1733322753429-968.png||data-xwiki-image-style-alignment="center"]] 315 315 316 -I,,peak,, = Maximum PEAK discharge current × K,,dp,, 309 +**I,,peak,, = Maximum PEAK discharge current × K,,dp,,** 317 317 318 -I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,, 311 +**I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,,** 319 319 320 320 === Main contactor === 321 321 322 -The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 315 +The BMS Main 3 / BMS Main 2R device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 323 323 324 324 The Main contactor algorithm supports the following modes: 325 325 326 -* Always on; 327 -* Automatic. 319 +In **“Always on”** mode main contactor closes if all the following is true: 328 328 329 -In “Always on” mode main contactor closes if all the following is true: 330 - 331 331 * Other contactors are open; 332 -* There are no errors from the "Errors 1, 2 ..." bitfileds. 322 +* There are __no errors__ from the "Errors 1, 2 ..." bitfileds. 333 333 334 - In “Always on” modemain contactor opens if all the following is true:324 +and opens if all the following is true: 335 335 336 336 * Other contactors are open; 337 -* There is an error from the the "Errors 1, 2 ..." bitfileds. 327 +* There is __an error__ from the the "Errors 1, 2 ..." bitfileds. 338 338 339 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 329 +In **“Automatic”** mode, the main contactor closes by internal algorithms at the same time with other contactors. 340 340 341 -In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 331 +In **“On demand”** mode, the main contactor closes by external the “Close Main contactor” request. 342 342 343 343 (% class="box infomessage" %) 344 344 ((( ... ... @@ -351,34 +351,35 @@ 351 351 352 352 In this section: 353 353 354 -* Enable – a flag to enable the main contactor control; 355 -* Algorithm – main contactor control algorithm: 356 -** Always on – contactor is always closed; 357 -** Automatic – contactor closes by internal charge and discharge algorithms; 358 -** On demand – contactor is closed by an external request; 359 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 360 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 361 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 362 -* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 344 +* **Enable **– a flag to enable the main contactor control; 345 +* **Algorithm** – main contactor control algorithm: 346 +** **Always on** – contactor is always closed; 347 +** **Automatic** – contactor closes by internal charge and discharge algorithms; 348 +** **On demand** – contactor is closed by an external request; 349 +* **Time to keep the contactor closed before closing the others** – a time for other contactors to be open after the main contactor is closed; 350 +* **Delay before opening the contactor** – a time which is used to detect conditions for opening the contactor, s; 351 +* **Keep the contactor open until the device is restarted** – a flag for keeping the main contactor open until the system is reset; 352 +* **Errors 1, 2 to open the main contactor** – bitfields to choose the errors which will open the main contactor. 363 363 364 364 === Charging status === 365 365 366 366 To change the parameters of charging process status, select the "Control → Charging status" section: 367 367 368 -[[image:17 60435790050-496.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="140" width="800"]]358 +[[image:1771432488941-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="800"]] 369 369 370 370 In this section: 371 371 372 -* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 373 -* Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 374 -* Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 375 -* Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 376 -* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 377 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 378 -* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal; 379 -* Charge current limit to clear the 'Ready to charge' – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared; 380 -* Charge current limit to set the 'Ready to charge' – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set; 381 -* Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 362 +* **Current to set the "Charging current present"** – a current level to generate the "Charging current present" signal, A; 363 +* **Current to clear the "Charging current present"** – a current level to clear the "Charging current present" signal, A; 364 +* **Voltage to clear the “Ready to charge”** – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 365 +* **Voltage to reset the “Ready to charge”** – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 366 +* **Use actual voltage to generate the "Ready to charge" signal** – a flag to disable voltage correction for "Ready to charge" signal; 367 +* **Treat negative currents as zero currents for generating the "Ready to charge" signal** – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 368 +* **Delay before recharging** – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 369 +* **Check the 'Charge current limit' value to generate the 'Ready to charge'** – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal; 370 +* **Charge current limit to clear the 'Ready to charge'** – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared; 371 +* **Charge current limit to set the 'Ready to charge'** – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set; 372 +* **Errors 1, 2 to clear the "Ready to charge"** – bitfields to choose the errors which will clear the "Ready to charge" signal. 382 382 383 383 (% class="box infomessage" %) 384 384 ((( ... ... @@ -391,48 +391,56 @@ 391 391 392 392 To change the parameters of discharging process status, select the "Control → Discharging status" section: 393 393 394 -[[image:17 60435802140-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]385 +[[image:1771431570393-551.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]] 395 395 396 396 In this section: 397 397 398 -* Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 399 -* Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 400 -* Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 401 -* Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 402 -* Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current; 403 -* Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 404 -* Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 405 -* Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 406 -* Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 389 +* **Current to set the "Discharging current present"** – a current level to generate the "Discharging current present" signal, А; 390 +* **Current to clear the "Discharging current present"** – a current level to clear the "Discharging current present" signal, А; 391 +* **Voltage to clear the “Ready to discharge”** – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 392 +* **Voltage to reset the “Ready to discharge”** – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 393 +* **Use actual voltage to generate the "Ready to discharge" signal** – a flag to disable voltage correction for "Ready to discharge" signal; 394 +* **Treat positive currents as zero currents for generating the "Ready to discharge" signal** – a flag to disable voltage correction for "Ready to discharge" signal at charging current; 395 +* **Check the 'Discharge current limit' value to generate the 'Ready to discharge'** – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 396 +* **Discharge current limit to clear the 'Ready to discharge'** – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 397 +* **Discharge current limit to set the 'Ready to discharge'** – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 398 +* **Clear the 'Ready to discharge' signal if the 'Low SOC' signal is set**; 399 +* **Errors 1, 2 to clear the "Ready to discharge"** – bitfields to choose the errors which will clear the "Ready to discharge" signal. 407 407 408 408 === Precharge === 409 409 410 -The BMS Main 3 device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor. 403 +The BMS Main 3 / BMS Main 2R device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor. 411 411 412 -BMS Main 3 devicedetectserrors while pre-charging theloadcapacityby monitoring the current and voltage difference before and after contactors.Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit.405 +BMS Main 3 can check the preacharge process by monitoring **the current and voltage difference** before and after contactors. 413 413 414 - TBA407 +BMS Main 2R can check the preacharge process **only by monitoring the current**. 415 415 409 +In **simple **mode precharge contactor closes a "Precharge time" before the closing of Charge or Discharge contactors and opens after the same amount of time after closing them. 410 + 411 +In **enhanced **mode precharge contactor will wait until the current of voltage difference requirements are met and close the Charge or Discharge contactors only after that. If waiting time is greater than "Precharge time" value, an error will be generated. Precharge contactor will open after "Precharge time" after closing the Charge of Discharge contactors. 412 + 413 +Also BMS Main 3 / BMS Main 2R can measure the power dissipated on precharge resistor and generate an error if it is greater than configured limit. 414 + 416 416 To change the parameters of precharge contactor, select the "Control → Precharge" section: 417 417 418 418 [[image:1750328428183-819.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="800"]] 419 419 420 -* Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 421 -* Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 422 -* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 423 -* Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay; 424 -* Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 425 -* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond; 426 -* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 427 -* Relaxation between attempts – a duration between precharge attempts, millisecond; 428 -* Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; 429 -* Precharge resistor resistance, Ohm; 430 -* Maximum allowable power dissipated in the resistor, W; 431 -* Delay before setting the "Precharge error" when checking power, millisecond; 432 -* Delay before clearing the "Precharge error", second; 433 -* Lock the "Precharge error" – a flag to block the error until the device is restarted. 419 +* **Precharge current threshold to finish precharging **– a minimum current value at which precharging process assumed to be finished, A; 420 +* **Check voltages before and after contactors to finish precharging **– a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 421 +* **Minimum voltage difference to finish precharging** – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 422 +* **Keep the precharging relay closed until precharge is finished** – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay; 423 +* **Number of precharging attempts** – maximum number of precharging attempts before setting the "Precharge error"; 424 +* **Delay before current measurement** – a delay before first current measurement after closing precharge, millisecond; 425 +* **Precharge time **– a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 426 +* **Relaxation between attempts **– a duration between precharge attempts, millisecond; 427 +* **Check the power dissipated in the preacharge resistor** - a flag to enable the calculation of power dissipated in precharge resistor; 428 +* **Precharge resistor resistance**, Ohm; 429 +* **Maximum allowable power dissipated in the resistor**, W; 430 +* **Delay before setting the "Precharge error" when checking power**, millisecond; 431 +* **Delay before clearing the "Precharge error"**, second; 432 +* **Lock the "Precharge error"** – a flag to block the error until the device is restarted. 434 434 435 -“Precharge error” generat ion conditions if any of the following is true:434 +“Precharge error” generates if any of the following is true: 436 436 437 437 * the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 438 438 * voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts"; ... ... @@ -445,39 +445,31 @@ 445 445 446 446 === Charge === 447 447 448 -There are two contactors that serve charging the battery:a chargingcontactor andan allow chargingcontactor. With the help of theallow chargingcontactor, the BMS commands the charger to start or stop charging.447 +There are two signals that serve charging the battery: "Charging" and "Allow charging". With the help of the "Allow charging" signal, the BMS commands the charger to start or stop charging. 449 449 450 - Thedevicesupports three charge control algorithms:449 +BMS Main 3 / BMS Main 2R supports three charge control algorithms: 451 451 452 -* Always on – charging is always allowed; 453 -* On charger connected – charging is allowed when there is a signal “Charger connected”; 454 -* On charge request – charging is allowed when there is a signal “Charge request”. 451 +If the "**Always on**" algorithm is selected, the "Сharging signals" and the "Allow charging" signals are always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 455 455 456 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 457 - 458 458 * Service reset; 459 459 * Power down request; 460 460 * Inhibit charging, 461 461 462 -both contactors areopen (nocurrent flows).457 +both signals are cleared. 463 463 464 464 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 465 465 466 -* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 467 -* If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 468 -* If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 469 -* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 461 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" and the "Allow charging" signal are set; 462 +* If the signal “Charger connected” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared. 470 470 471 471 When the "**On charge request**" algorithm selected, the control is performed as follows: 472 472 473 -* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 474 -* If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 475 -* If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 476 -* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 466 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" and the "Allow charging" signal are set; 467 +* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared; 477 477 478 478 (% class="box infomessage" %) 479 479 ((( 480 -**Note: **when errors occur in the system, the **Charg e**contactoropenseither immediately or with the delay T,,off,, (depends on the settings described below).471 +**Note: **when errors occur in the system, the **"Charing" **signal is cleared either immediately or with the delay T,,off,, (depends on the settings described below). 481 481 ))) 482 482 483 483 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: ... ... @@ -486,41 +486,37 @@ 486 486 487 487 In this section: 488 488 489 -* Enable – a flag to activate the charge control; 490 -* Algorithm: 491 -** Always on – charging is always allowed; 492 -** On charger connected – charging is allowed when there is a signal “Charger connected”; 493 -** On charge request – charging is allowed when there is a signal “Charge request”; 494 -* Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 495 -* Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 496 -* Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 497 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]); 498 -* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 499 -* Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 500 -* Custom delay: <error> – delay for specific error, millisecond; 501 -* Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 480 +* **Enable **– a flag to activate the charge control; 481 +* **Algorithm**: 482 +** **Always on** – charging is always allowed; 483 +** **On charger connected** – charging is allowed when there is a signal “Charger connected”; 484 +** **On charge request** – charging is allowed when there is a signal “Charge request”; 485 +* **Allow charging only when the "Ready to charge" signal is set** – charging contactor will open if "Ready to charge" signal is cleared; 486 +* **Delay before starting charging** – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 487 +* **Delay before stopping charging** – a time delay T,,off,, before opening the charging contactor, millisecond; 488 +* **Control the precharging contactor** – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]); 489 +* **Errors 1, 2 to open the charging contactor** – bitfields to choose the errors which will open the charging contactor; 490 +* **Use custom delays before stopping charging (on errors)** – a flag to enable manual settings of time delays T,,off,, for specific errors; 491 +* **Custom delay: <error>** – delay for specific error, millisecond; 492 +* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 502 502 503 503 === Discharge === 504 504 505 -The devicecontrolsthedischargingcontactortoconnect battery to the load.496 +The BMS Main 3 / BMS Main 2R device connect battery to the load using the "Discharging" signal. 506 506 507 - Thedevicesupports three algorithms to control battery discharging:498 +BMS Main 3 / BMS Main 2R supports three algorithms to control battery discharging: 508 508 509 -* Always on – load is always connected; 510 -* On charger disconnected – load is connected when there is no signal “Charger connected”; 511 -* On discharge request – load is connected when there is signal “Discharge request”. 500 +When the algorithm "**Always on**" is selected, the "Discharging" signal is always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 512 512 513 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 514 - 515 515 * Service reset 516 516 * Power down request 517 517 * Inhibit discharging 518 518 519 -the dischargingcontactoropens.506 +the "Discharging" signal is cleared. 520 520 521 521 If the algorithm "**On charger disconnected**" is selected, the control is performed as follows: 522 522 523 -* if there is no signal“Charger connected”,thechargingcontactor isopenand there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, thedischarging contactor closes;510 +* if there is no “Charger connected” and "Charging" signals and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Discharging" contactor closes; 524 524 * If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 525 525 526 526 When the "**On discharge request**" algorithm selected, the control is performed as follows: ... ... @@ -539,32 +539,45 @@ 539 539 540 540 In this section: 541 541 542 -* Enable – a flag to activate the discharge control; 543 -* Algorithm: 544 -** Always on – load is always connected; 545 -** On charger disconnected – load is connected when there is no signal “Charger connected”; 546 -** On discharge request – load is connected when there is signal “Discharge request”; 547 -* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 548 -* Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 549 -* Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 550 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]); 551 -* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 552 -* Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 553 -* Custom delay: <error> – specific error delay, millisecond; 554 -* Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 529 +* **Enable **– a flag to activate the discharge control; 530 +* **Algorithm**: 531 +** **Always on** – load is always connected; 532 +** **On charger disconnected** – load is connected when there is no signal “Charger connected”; 533 +** **On discharge request** – load is connected when there is signal “Discharge request”; 534 +* **Allow charging only when the "Ready to discharge" signal is set** – discharging contactor will open if "Ready to discharge" signal is cleared; 535 +* **Delay before starting discharging** – a time delay T,,on,, before closing the discharging contactor, millisecond; 536 +* **Delay before stopping discharging** – a time delay T,,off,, before opening the discharging contactor, millisecond; 537 +* **Control the precharging contactor** – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]); 538 +* **Errors 1, 2 to open the discharging contactor** – bitfields to choose the errors which will open the discharging contactor; 539 +* **Use custom delays before stopping discharging (on errors)** – a flag to enable manual settings of time delays T,,off,, for specific errors; 540 +* **Custom delay: <error>** – specific error delay, millisecond; 541 +* **Switch off the discharging contactor on errors without delay** – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 555 555 556 556 === Charge/Discharge === 557 557 558 -The BMS Main 3 device can control the charge/discharge contactor, which combines algorithms of charging and discharging contactor.545 +The BMS Main 3 / BMS Main 2R device can control the Charge/Discharge contactor, which combines algorithms of charging and discharging contactor. 559 559 560 560 Charge/Discharge contactor has three algorithms of operation: 561 561 562 -* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 563 -* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 564 -* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs. 549 +On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge controllers and behaves: 565 565 566 -TBA 551 +* as Charging contactor if "Charging" signal is set; 552 +* as Discharging contactor in other cases. 567 567 554 +When **Independent (Always) **algorithm is selected, the charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 555 + 556 +* Service reset 557 +* Power down request 558 +* Inhibit charging 559 +* Inhibit discharging 560 + 561 +the charging/discharging contactor opens. 562 + 563 +On **Independent (on Charge request or Discharge request)** algorithm charge/discharge contactor is based on its own controller and performs as follows: 564 + 565 +* if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging/discharging contactor closes; 566 +* If the "Charge request" or "Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the charging/discharging contactor opens. 567 + 568 568 (% class="box infomessage" %) 569 569 ((( 570 570 **Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). ... ... @@ -576,23 +576,23 @@ 576 576 577 577 In this section: 578 578 579 -* Enable – a flag to enable the charge/discharge controller. 580 -* Algorithm: 581 -** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 582 -** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 583 -** Independent (on Charge request or Discharge request); 584 -* Delay before starting charging or discharging, millisecond; 585 -* Delay before stopping charging or discharging, millisecond; 586 -* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 587 -* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 588 -* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 589 -* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 590 -* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; 591 -* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”. 579 +* **Enable **– a flag to enable the charge/discharge controller. 580 +* **Algorithm**: 581 +** **Dependent (on Charging and Discharging signals)** - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 582 +** **Independent (Always)** - Charge/Discharge contactor is always closed if there is no errors; 583 +** **Independent (on Charge request or Discharge request)**; 584 +* **Delay before starting charging or discharging**, millisecond; 585 +* **Delay before stopping charging or discharging**, millisecond; 586 +* **Control the precharging contactor** – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 587 +* **Emulate the "Charging" and "Discharging" signals** – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 588 +* **Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor** – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 589 +* **Errors 1, 2 which affect the contactor only if battery CHARGING is detected** – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 590 +* **Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected** – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; 591 +* **Switch off the charging/discharging contactor on errors without delay** – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”. 592 592 593 593 === Discharge (AUX) === 594 594 595 -The BMS Main 3 device can control the power supply of external equipment using the auxiliary (AUX) discharging contactor. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices. 595 +The BMS Main 3 / BMS Main 2R device can control the power supply of external equipment using the auxiliary (AUX) discharging contactor. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices. 596 596 597 597 The power supply circuit of the external equipment using the auxiliary (AUX) discharging contactor is independent of the battery load circuit. The closing and opening of the auxiliary (AUX) discharging contactor is performed according to its program. 598 598 ... ... @@ -608,27 +608,27 @@ 608 608 609 609 In this section: 610 610 611 -* Enable – a flag to activate the auxiliary discharge control; 612 -* Switch off the discharging (AUX) contactor if the SOC is too low; 613 -* Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 614 -* Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 615 -* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 616 -* Minimum cell voltage, V; 617 -* Maximum cell voltage, V; 618 -* Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 619 -* Minimum battery voltage, V; 620 -* Maximum battery voltage, V; 621 -* Errors 1, 2 to open the auxiliary discharging contactor – bitfields to choose the errors which will open the auxiliary discharging contactor. 611 +* **Enable **– a flag to activate the auxiliary discharge control; 612 +* **Switch off the discharging (AUX) contactor if the SOC is too low**; 613 +* **Minimum SOC** – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 614 +* **Tolerant SOC** – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 615 +* **Switch off the discharging (AUX) contactor if the cell voltage is out of the range**; 616 +* **Minimum cell voltage**, V; 617 +* **Maximum cell voltage**, V; 618 +* **Switch off the discharging (AUX) contactor if the battery voltage is out of the range**; 619 +* **Minimum battery voltage**, V; 620 +* **Maximum battery voltage**, V; 621 +* **Errors 1, 2 to open the auxiliary discharging contactor** – bitfields to choose the errors which will open the auxiliary discharging contactor. 622 622 623 623 === Cell balancing === 624 624 625 625 Balancing makes the voltage of all cells equal to the minimum cell voltage. 626 626 627 -The following balancing rules are supported: 627 +The following **balancing rules** are supported: 628 628 629 -* when the battery is charging (current I > 0) and time after until the battery is relaxed; 630 -* when the battery is charging (current I > 0) or when the battery is in a state of relaxation; 631 -* always (regardless of battery state).629 +* **Balance on charge** – perform balancing when the battery is charging (current I > 0) and time after until the battery is relaxed; 630 +* **Balance on charge or relaxed** – perform balancing when the battery is charging (current I > 0) or when the battery is in a state of relaxation ; 631 +* **Balance always** regardless of battery state. 632 632 633 633 A balancing resistor is connected to the cell if the following conditions are simultaneously met: 634 634 ... ... @@ -645,9 +645,9 @@ 645 645 If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed. 646 646 ))) 647 647 648 -The BMS Main 3 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 648 +The BMS Main 3 / BMS Main 2R can enable the cell balancing by the external **“Balancing request”** signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 649 649 650 -BMS Main 3 can force a cellbalancing, if its voltage is higher than estimated value.650 +BMS Main 3 / BMS Main 2R can **force balancing **of the cell, if its voltage is higher than estimated value. 651 651 652 652 To change the cell balancing parameters, select the "Control → Cell balancing" section: 653 653 ... ... @@ -655,24 +655,25 @@ 655 655 656 656 In this section: 657 657 658 -* Enable – a flag to enable cell balancing; 659 -* Balancing rule: 660 -** Balance on charge – balancing is performed while and after the charging (in the “Charge ON” and “Charge OFF” states); 661 -** Balance on charge or relaxed - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states); 662 -** Balance always – balancing is always performed regardless the battery state; 663 -* Balancing condition: 664 -** Automatic – balancing will be performed automatically if needed conditions are met; 665 -** On balancing request – balancing will start only if a remote request is received. In this case cells will start to balance regardless the "Voltage deviation to start balancing" value; 666 -* Minimum cell voltage to start balancing, V; 667 -* Voltage deviation to start balancing; 668 -* Voltage deviation to stop balancing; 669 -* Voltage for forced balancing – if cell voltage is above this value, it will start discharging through balancing resistor; 670 -* Maximum allowable temperature of BMS Logic devices, ºC; 671 -* Command to discharge all cells – a flag to force the balancing of all cells. 658 +* **Enable **– a flag to enable cell balancing; 659 +* **Balancing rule**: 660 +** **Balance on charge** – balancing is performed while and after the charging (in the “Charge ON” and “Charge OFF” states); 661 +** **Balance on charge or relaxed** - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states); 662 +** **Balance always** – balancing is always performed regardless the battery state; 663 +* **Balancing condition**: 664 +** **Automatic **– balancing will be performed automatically if needed conditions are met; 665 +** **On balancing request** – balancing will start only if a remote request is received. In this case cells will start to balance regardless the "Voltage deviation to start balancing" value; 666 +* **Minimum cell voltage to start balancing**, V; 667 +* **Voltage deviation to start balancing**; 668 +* **Voltage deviation to stop balancing**; 669 +* **Voltage to start forced balancing** – if cell voltage is above this value, it will start discharging through balancing resistor; 670 +* **Voltage to stop forced balancing** – if cell voltage is below this value, it will stop discharging through balancing resistor; 671 +* **Maximum allowable temperature of BMS Logic devices**, ºC; 672 +* **Command to discharge all cells** – a flag to force the balancing of all cells. 672 672 673 673 === Series balancing === 674 674 675 -The BMS Main 3 device supports work with two independent (galvanically unrelated) cell series. To monitor the status of two series, two current sensors are used. A series of cells must be equivalent: they must have the same number of cells and the same capacity. 676 +The BMS Main 3 / BMS Main 2R device supports work with two independent (galvanically unrelated) cell series. To monitor the status of two series, two current sensors are used. A series of cells must be equivalent: they must have the same number of cells and the same capacity. 676 676 677 677 Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 3 provides two signals to power switches: “Balancing series 1” and “Balancing series 2”, as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. The “Balancing series 1” and “Balancing series 2” signals are used to connect high-power balancing resistors in parallel with cell series 1 and 2. 678 678 ... ... @@ -689,17 +689,17 @@ 689 689 690 690 In this section: 691 691 692 -* Enable – a flag to enable series balancing; 693 -* Number of Logics in a series; 694 -* Minimum series voltage to start balancing, V; 695 -* Balancing threshold, V; 696 -* Coulomb threshold – the difference of the charges Qthr, given by a series of cells, above which balancing to be started, Ah; 697 -* Period – a period to reset of charge counters for each series (to avoid accumulation of error), second; 698 -* Do not sum series voltages – a flag to disable the summing of series voltages. 3693 +* **Enable **– a flag to enable series balancing; 694 +* **Number of Logics in a series**; 695 +* **Minimum series voltage to start balancing**, V; 696 +* **Balancing threshold**, V; 697 +* **Coulomb threshold** – the difference of the charges Qthr, given by a series of cells, above which balancing to be started, Ah; 698 +* **Period **– a period to reset of charge counters for each series (to avoid accumulation of error), second; 699 +* **Do not sum series voltages** – a flag to disable the summing of series voltages. 699 699 700 700 === Power down === 701 701 702 -The BMS Main 3 device can shut down itself if the battery voltage is low or the battery is idle for a long time. 703 +The BMS Main 3 / BMS Main 2R device can shut down itself if the battery voltage is low or the battery is idle for a long time. 703 703 704 704 Shutting down the battery system is performed according to the following conditions: 705 705 ... ... @@ -706,7 +706,7 @@ 706 706 * the battery voltage is below the minimum level; 707 707 * the “Charger connected” signal is cleared for 60 seconds. 708 708 709 -The BMS Main 3 device also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” forthe configuredtime.710 +The BMS Main 3 device also shuts down the battery if it **stays for a long time **in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” state. 710 710 711 711 To change the parameters of the power down control, select the "Control → Power down" section: 712 712 ... ... @@ -714,11 +714,11 @@ 714 714 715 715 In this section: 716 716 717 -* Minimum voltage to power down – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 718 -* Idle time to power down – a time of battery inactivity after which the battery is shut down, minute; 719 -* Wait the "Power up/down request" is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS. 720 -* Power down if KEYRUN and CHARGE_ON are cleared – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared; 721 -* Delay before setting the internal power down signal – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms. 718 +* **Minimum voltage to power down** – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 719 +* **Idle time to power down** – a time of battery inactivity after which the battery is shut down, minute; 720 +* **Wait the "Power up/down request" is cleared (on startup)** – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS. 721 +* **Power down if KEYRUN and CHARGE_ON are cleared** – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared; 722 +* **Delay before setting the internal power down signal** – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms. 722 722 723 723 === Heater === 724 724 ... ... @@ -728,22 +728,24 @@ 728 728 729 729 In this section: 730 730 731 -* Enable – a flag to enable the heater control; 732 -* Minimum cell temperature, °C; 733 -* Tolerant cell temperature, °C; 734 -* Delay before starting the heater, millisecond; 735 -* Delay before stopping the heater, millisecond; 736 -* Switchoffthe heateronerrors(Undervoltage,Overcurrent,Hightemperature, ShortcircuitorCriticalerror).732 +* **Enable **– a flag to enable the heater control; 733 +* **Minimum cell temperature**, °C; 734 +* **Tolerant cell temperature**, °C; 735 +* **Delay before starting the heater**, millisecond; 736 +* **Delay before stopping the heater**, millisecond; 737 +* **Errors 1, 2 to open the heater** – bitfields to choose the errors which will open the heater. 737 737 738 738 As a result of operating the heating algorithm, the “Heater” signal is generated. 739 739 740 740 Conditions for signal generation: 741 741 742 -* the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time. 743 +* the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time; 744 +* there are no errors from "Errors 1, 2..." bitfields. 743 743 744 744 Conditions for clearing the signal: 745 745 746 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 748 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time; 749 +* there is an error from "Errors 1, 2..." bitfields. 747 747 748 748 (% class="box infomessage" %) 749 749 ((( ... ... @@ -758,22 +758,24 @@ 758 758 759 759 In this section: 760 760 761 -* Enable – a flag to enable the cooler control; 762 -* Maximum cell temperature, °C; 763 -* Tolerant cell temperature, °C; 764 -* Delay before starting the cooler, millisecond; 765 -* Delay before stopping the cooler, millisecond; 766 -* Switchoffthe coolercontactoron errors(Undervoltage,Overcurrent, Low temperature,Short circuitorCriticalerror).764 +* **Enable** – a flag to enable the cooler control; 765 +* **Maximum cell temperature**, °C; 766 +* **Tolerant cell temperature**, °C; 767 +* **Delay before starting the cooler**, millisecond; 768 +* **Delay before stopping the cooler**, millisecond; 769 +* **Errors 1, 2 to open the cooler **– bitfields to choose the errors which will open the cooler. 767 767 768 768 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 769 769 770 770 Conditions for signal generation: 771 771 772 -* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time. 775 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time; 776 +* there are no errors from "Errors 1, 2..." bitfields. 773 773 774 774 Conditions for clearing the signal: 775 775 776 -* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 780 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time; 781 +* there is an error from "Errors 1, 2..." bitfields. 777 777 778 778 (% class="box infomessage" %) 779 779 ((( ... ... @@ -782,6 +782,11 @@ 782 782 783 783 === High voltage === 784 784 790 +(% class="box warningmessage" %) 791 +((( 792 +This section is not available on BMS Main 2R. 793 +))) 794 + 785 785 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 786 786 787 787 To change the parameters of high voltage fault, select the "Control → High voltage" section: ... ... @@ -790,9 +790,9 @@ 790 790 791 791 In this section: 792 792 793 -* Enable – a flag to enable High voltage control; 794 -* Delay before clearing the High voltage fault, second; 795 -* Lock the High voltage fault. 803 +* **Enable **– a flag to enable High voltage control; 804 +* **Delay before clearing the High voltage fault**, second; 805 +* **Lock the High voltage fault**. 796 796 797 797 The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated. 798 798 ... ... @@ -805,7 +805,7 @@ 805 805 806 806 The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level. 807 807 808 -The BMS Main 3 device can automatically determine the battery discharge characteristic. 818 +The BMS Main 3 / BMS Main 2R device can automatically determine the battery discharge characteristic. 809 809 810 810 Before starting the process of determining the discharge characteristic, it is necessary to prepare a BMS: 811 811 ... ... @@ -818,18 +818,14 @@ 818 818 819 819 In this section: 820 820 821 -* Enable – a flag to enable cell analysis; 822 -* Discharge step, Ah; 823 -* Delta voltage – a maximum allowable voltage drop for the cell, V; 824 -* Logic index, Cell index – a position of the analyzed cell; 825 -* Analyse the most discharged cell – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored). 831 +* **Enable **– a flag to enable cell analysis; 832 +* **Discharge step**, Ah; 833 +* **Delta voltage** – a maximum allowable voltage drop for the cell, V; 834 +* **Logic index, Cell index** – a position of the analyzed cell; 835 +* **Analyse the most discharged cell** – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored). 826 826 827 -Discharge step should be set equal to 837 +Discharge step should be set equal to С/21, where C is the cell capacity. 828 828 829 -Discharge step= С/21, 830 - 831 -where C is the cell capacity. 832 - 833 833 The discharge characteristic will be constructed for the given cell (its position is determined by the fields “Logic index” and “Cell index”). 834 834 835 835 The algorithm for determining the discharge characteristic of the battery will be started if the “Enable” flag is set. From this moment, the control of the discharge contactor is performed by this algorithm.
- 1765447975228-766.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.8 KB - Content
- 1765448283865-334.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.9 KB - Content
- 1771431551882-439.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.7 KB - Content
- 1771431570393-551.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.7 KB - Content
- 1771432488941-251.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.1 KB - Content
- 1771432563405-644.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.1 KB - Content