Changes for page 3.3 Control
Last modified by Admin on 2025/12/11 10:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -102,15 +102,6 @@ 102 102 * Ignore the linear zone – a flag to ignore linear SOC zone while correction (recommended to be unset); 103 103 * Last correction timestamp – time when last correction was made. 104 104 105 -=== SOH estimation === 106 - 107 -The BMS Main 3 device calculates the state of health of the battery (SOH) using two algorithms: 108 - 109 -* by effective capacity; 110 -* by total charge-. 111 - 112 -In "By effective capacity" mode SOH is calculated as 113 - 114 114 === Resistance estimation === 115 115 116 116 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value ... ... @@ -365,7 +365,7 @@ 365 365 366 366 To change the parameters of charging process status, select the "Control → Charging status" section: 367 367 368 -[[image:17 60435790050-496.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="140" width="800"]]359 +[[image:1750261016583-434.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 369 369 370 370 In this section: 371 371 ... ... @@ -375,9 +375,6 @@ 375 375 * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 376 376 * Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 377 377 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 378 -* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal; 379 -* Charge current limit to clear the 'Ready to charge' – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared; 380 -* Charge current limit to set the 'Ready to charge' – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set; 381 381 * Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 382 382 383 383 (% class="box infomessage" %) ... ... @@ -391,7 +391,7 @@ 391 391 392 392 To change the parameters of discharging process status, select the "Control → Discharging status" section: 393 393 394 -[[image:17 60435802140-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]382 +[[image:1750261289590-730.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]] 395 395 396 396 In this section: 397 397 ... ... @@ -400,9 +400,6 @@ 400 400 * Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 401 401 * Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 402 402 * Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current; 403 -* Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 404 -* Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 405 -* Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 406 406 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 407 407 408 408 === Precharge ===