... ... @@ -367,7 +367,8 @@
367 367  * Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
368 368  * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
369 369  * Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;
370 -* Charge current limit to clear the 'Ready to charge' – a threshold ; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;
370 +* Charge current limit to clear the 'Ready to charge' – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;
371 +* Charge current limit to set the 'Ready to charge' – a tolerant charging current limit value, A; if the limit is //below//this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;
371 371  * Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal.