Changes for page 3.3 Control

Last modified by Admin on 2025/12/11 10:32

From version 63.2
edited by Admin
on 2025/10/14 09:57
Change comment: There is no comment for this version
To version 63.3
edited by Admin
on 2025/10/14 09:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -366,7 +366,8 @@
366 366  * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set;
367 367  * Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
368 368  * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
369 -* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable
369 +* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;
370 +* Charge current limit to clear the 'Ready to charge' – a threshold ; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;
370 370  * Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal.
371 371  
372 372  (% class="box infomessage" %)