Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 To change the common BMS settings, select the "Control → Common settings" section: 10 10 11 -[[image:173 3322611547-671.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]11 +[[image:1735054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 12 12 13 13 In this section: 14 14 ... ... @@ -16,8 +16,10 @@ 16 16 * Cell resistance – nominal (maximum) internal resistance of the cells, Ohm; 17 17 * Relax time (after charging) – a relaxation time after charging, second; 18 18 * Relax time (atfer discharging) – a relaxation time after discharging, second; 19 -* Number of cycles – a number of charge-discharge cycles; 20 -* Reset parameters – a command to reset cells state of charge, capacity, and resistance. 19 +* Reset parameters – a command to reset cells state of charge, capacity, and resistance; 20 +* Method of calculating the battery voltage: 21 +** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery; 22 +** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS. 21 21 22 22 The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery. 23 23