405 405  * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A;
406 406  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
407 407  * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V;
408 -* Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
409 409  * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error";
410 410  * Delay before current measurement – a delay before first current measurement after closing precharge, millisecond;
411 411  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;