... ... @@ -406,7 +406,7 @@
406 406  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
407 407  * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V;
408 408  * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error";
409 -* Delay before current measurement – a delay before first current measurement after BMS , millisecond;
409 +* Delay before current measurement, millisecond;
410 410  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
411 411  * Relaxation between attempts – a duration between precharge attempts, millisecond;
412 412  * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor;