Changes for page 3.3 Control
Last modified by Admin on 2025/06/19 10:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -400,12 +400,13 @@ 400 400 401 401 To change the parameters of precharge contactor, select the "Control → Precharge" section: 402 402 403 -[[image:17502 61478365-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="800"]]403 +[[image:1750328428183-819.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="800"]] 404 404 405 405 * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 406 406 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 407 407 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 408 408 * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 409 +* Delay before current measurement – a delay before first current measurement a, millisecond; 409 409 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 410 410 * Relaxation between attempts – a duration between precharge attempts, millisecond; 411 411 * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor;