Changes for page 3.3 Control
Last modified by Admin on 2025/06/19 10:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -364,7 +364,7 @@ 364 364 * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 365 365 * Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 366 366 * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 367 -* Treat positive currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready todischarge" signal at charging current367 +* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 368 368 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 369 369 * Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 370 370 ... ... @@ -379,12 +379,15 @@ 379 379 380 380 To change the parameters of discharging process status, select the "Control → Discharging status" section: 381 381 382 -[[image:17 35064980481-209.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]In this section:382 +[[image:1750261289590-730.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]] 383 383 384 +In this section: 385 + 384 384 * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 385 385 * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 386 386 * Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 387 387 * Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 390 +* Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current; 388 388 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 389 389 390 390 === Precharge === ... ... @@ -397,12 +397,13 @@ 397 397 398 398 To change the parameters of precharge contactor, select the "Control → Precharge" section: 399 399 400 -[[image:17 35065073836-743.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="160" width="800"]]403 +[[image:1750328428183-819.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="800"]] 401 401 402 402 * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 403 403 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 404 404 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 405 405 * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 409 +* Delay before current measurement – a delay before first current meas, millisecond; 406 406 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 407 407 * Relaxation between attempts – a duration between precharge attempts, millisecond; 408 408 * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor;
- 1750261281846-185.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +0 bytes - Content
- 1750261289590-730.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.3 KB - Content
- 1750261478365-882.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.9 KB - Content
- 1750328428183-819.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.4 KB - Content