... ... @@ -457,6 +457,7 @@
457 457  **Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
458 458  )))
459 459  
460 +
460 460  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
461 461  
462 462  [[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
... ... @@ -471,7 +471,7 @@
471 471  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
472 472  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
473 473  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
474 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);
475 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
475 475  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
476 476  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
477 477  * Custom delay: <error> – delay for specific error, millisecond;
... ... @@ -510,6 +510,8 @@
510 510  **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
511 511  )))
512 512  
514 +The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]).
515 +
513 513  To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section:
514 514  
515 515  [[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]]
... ... @@ -524,7 +524,7 @@
524 524  * Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared;
525 525  * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond;
526 526  * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond;
527 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]);
530 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor;
528 528  * Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor;
529 529  * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
530 530  * Custom delay: <error> – specific error delay, millisecond;