Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,7 +21,7 @@ 21 21 ** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery; 22 22 ** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS. 23 23 24 -The values “Capacity” and“Resistance” are used to calculate the SOC of cells and the battery.24 +The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery. 25 25 26 26 The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. 27 27 ... ... @@ -71,7 +71,7 @@ 71 71 * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells; 72 72 * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC; 73 73 * Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC; 74 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC .74 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC; 75 75 76 76 Other parameters: 77 77 ... ... @@ -315,7 +315,8 @@ 315 315 The Main contactor algorithm supports the following modes: 316 316 317 317 * Always on; 318 -* Automatic. 318 +* Automatic; 319 +* On demand. 319 319 320 320 In “Always on” mode main contactor closes if all the following is true: 321 321 ... ... @@ -471,7 +471,7 @@ 471 471 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 472 472 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 473 473 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 474 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);475 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor; 475 475 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 476 476 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 477 477 * Custom delay: <error> – delay for specific error, millisecond; ... ... @@ -510,6 +510,8 @@ 510 510 **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 511 511 ))) 512 512 514 +The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]). 515 + 513 513 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 514 514 515 515 [[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]] ... ... @@ -524,7 +524,7 @@ 524 524 * Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 525 525 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 526 526 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 527 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]);530 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor; 528 528 * Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 529 529 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 530 530 * Custom delay: <error> – specific error delay, millisecond; ... ... @@ -619,7 +619,7 @@ 619 619 620 620 A balancing resistor is disconnected from the cell if any of the following conditions are met: 621 621 622 -* the voltage on the cell is less than the balancing st opvoltage;625 +* the voltage on the cell is less than the balancing start voltage; 623 623 * the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold. 624 624 625 625 If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed. ... ... @@ -626,7 +626,7 @@ 626 626 627 627 The BMS Main 3 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 628 628 629 -BMS Main 3 can force a cell balancing, if its voltage is highe r than estimated value.632 +BMS Main 3 can force a cell balancing, if its voltage is highe 630 630 631 631 To change the cell balancing parameters, select the "Control → Cell balancing" section: 632 632