Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -457,7 +457,6 @@ 457 457 **Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 458 458 ))) 459 459 460 - 461 461 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 462 462 463 463 [[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]] ... ... @@ -472,7 +472,7 @@ 472 472 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 473 473 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 474 474 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 475 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor; 474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]); 476 476 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 477 477 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 478 478 * Custom delay: <error> – delay for specific error, millisecond; ... ... @@ -511,8 +511,6 @@ 511 511 **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 512 512 ))) 513 513 514 -The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]). 515 - 516 516 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 517 517 518 518 [[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]] ... ... @@ -527,7 +527,7 @@ 527 527 * Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 528 528 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 529 529 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 530 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor; 527 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]); 531 531 * Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 532 532 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 533 533 * Custom delay: <error> – specific error delay, millisecond;