... ... @@ -457,7 +457,6 @@
457 457  **Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
458 458  )))
459 459  
460 -
461 461  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
462 462  
463 463  [[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
... ... @@ -472,7 +472,7 @@
472 472  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
473 473  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
474 474  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
475 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);
476 476  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
477 477  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
478 478  * Custom delay: <error> – delay for specific error, millisecond;
... ... @@ -511,8 +511,6 @@
511 511  **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
512 512  )))
513 513  
514 -The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]).
515 -
516 516  To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section:
517 517  
518 518  [[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]]
... ... @@ -527,7 +527,7 @@
527 527  * Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared;
528 528  * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond;
529 529  * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond;
530 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor;
527 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]);
531 531  * Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor;
532 532  * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
533 533  * Custom delay: <error> – specific error delay, millisecond;