Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 42.4
edited by Admin
on 2025/02/24 12:18
Change comment: There is no comment for this version
To version 42.5
edited by Admin
on 2025/02/24 12:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -457,7 +457,6 @@
457 457  **Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
458 458  )))
459 459  
460 -
461 461  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
462 462  
463 463  [[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
... ... @@ -472,7 +472,7 @@
472 472  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
473 473  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
474 474  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
475 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);
476 476  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
477 477  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
478 478  * Custom delay: <error> – delay for specific error, millisecond;