Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -471,7 +471,7 @@ 471 471 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 472 472 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 473 473 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 474 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor; 474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]); 475 475 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 476 476 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 477 477 * Custom delay: <error> – delay for specific error, millisecond;