... ... @@ -471,7 +471,7 @@
471 471  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
472 472  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
473 473  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
474 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);
475 475  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
476 476  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
477 477  * Custom delay: <error> – delay for specific error, millisecond;