... ... @@ -71,7 +71,7 @@
71 71  * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells;
72 72  * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC;
73 73  * Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC;
74 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC;
74 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC.
75 75  
76 76  Other parameters:
77 77  
... ... @@ -471,7 +471,7 @@
471 471  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
472 472  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
473 473  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
474 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]);
475 475  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
476 476  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
477 477  * Custom delay: <error> – delay for specific error, millisecond;
... ... @@ -510,8 +510,6 @@
510 510  **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
511 511  )))
512 512  
513 -The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]).
514 -
515 515  To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section:
516 516  
517 517  [[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]]
... ... @@ -526,7 +526,7 @@
526 526  * Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared;
527 527  * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond;
528 528  * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond;
529 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor;
527 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]);
530 530  * Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor;
531 531  * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
532 532  * Custom delay: <error> – specific error delay, millisecond;