Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,7 +21,7 @@ 21 21 ** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery; 22 22 ** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS. 23 23 24 -The values “Capacity” and“Resistance” are used to calculate the SOC of cells and the battery.24 +The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery. 25 25 26 26 The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. 27 27