... ... @@ -315,7 +315,8 @@ 315 315 The Main contactor algorithm supports the following modes: 316 316 317 317 * Always on; 318 -* Automatic. 318 +* Automatic; 319 +* On demand. 319 319 320 320 In “Always on” mode main contactor closes if all the following is true: 321 321 ... ... @@ -621,7 +621,7 @@ 621 621 622 622 A balancing resistor is disconnected from the cell if any of the following conditions are met: 623 623 624 -* the voltage on the cell is less than the balancing st opvoltage;625 +* the voltage on the cell is less than the balancing start voltage; 625 625 * the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold. 626 626 627 627 If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed. ... ... @@ -628,7 +628,7 @@ 628 628 629 629 The BMS Main 3 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 630 630 631 -BMS Main 3 can force a cell balancing, if its voltage is higher than estimated value.632 +BMS Main 3 can force a cell balancing, if its voltage is higher than 632 632 633 633 To change the cell balancing parameters, select the "Control → Cell balancing" section: 634 634