622 622  
623 623  A balancing resistor is disconnected from the cell if any of the following conditions are met:
624 624  
625 -* the voltage on the cell is less than the balancing stop voltage;
625 +* the voltage on the cell is less than the balancing start voltage;
626 626  * the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold.
627 627  
628 628  If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed.
... ... @@ -629,7 +629,7 @@
629 629  
630 630  The BMS Main 3 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold.
631 631  
632 -BMS Main 3 can force a cell balancing, if its voltage is higher than estimated value.