Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 40.1
edited by Admin
on 2025/02/17 17:25
Change comment: There is no comment for this version
To version 42.3
edited by Admin
on 2025/02/24 10:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -21,7 +21,7 @@
21 21  ** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery;
22 22  ** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS.
23 23  
24 -The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery.
24 +The values “Capacity” and “Resistance” are used to calculate the SOC of cells and the battery.
25 25  
26 26  The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
27 27  
... ... @@ -71,7 +71,7 @@
71 71  * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells;
72 72  * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC;
73 73  * Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC;
74 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC;
74 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC.
75 75  
76 76  Other parameters:
77 77  
... ... @@ -315,8 +315,7 @@
315 315  The Main contactor algorithm supports the following modes:
316 316  
317 317  * Always on;
318 -* Automatic;
319 -* On demand.
318 +* Automatic.
320 320  
321 321  In “Always on” mode main contactor closes if all the following is true:
322 322  
... ... @@ -622,7 +622,7 @@
622 622  
623 623  A balancing resistor is disconnected from the cell if any of the following conditions are met:
624 624  
625 -* the voltage on the cell is less than the balancing start voltage;
624 +* the voltage on the cell is less than the balancing stop voltage;
626 626  * the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold.
627 627  
628 628  If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed.