... ... @@ -8,7 +8,7 @@
8 8  
9 9  To change the common BMS settings, select the "Control → Common settings" section:
10 10  
11 -[[image:1733322611547-671.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
11 +[[image:1735054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]
12 12  
13 13  In this section:
14 14  
... ... @@ -16,8 +16,9 @@
16 16  * Cell resistance – nominal (maximum) internal resistance of the cells, Ohm;
17 17  * Relax time (after charging) – a relaxation time after charging, second;
18 18  * Relax time (atfer discharging) – a relaxation time after discharging, second;
19 -* Number of cycles – a number of charge-discharge cycles;
20 -* Reset parameters – a command to reset cells state of charge, capacity, and resistance.
19 +* Reset parameters – a command to reset cells state of charge, capacity, and resistance;
20 +* Method of calculating the battery voltage:
21 +** Summariza
21 21  
22 22  The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery.
23 23  
... ... @@ -83,7 +83,7 @@
83 83  
84 84  === SOC correction ===
85 85  
86 -The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section** **2.3.2).
87 +The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[SOC estimation>>doc:||anchor="HSOCestimation"]]).
87 87  
88 88  To configure parameters for periodically correcting the battery state of charge, select the "Control → SOC correction" section:
89 89  
... ... @@ -128,7 +128,7 @@
128 128  * Minimum SOC – minimum cell SOC value for resistance calculation;
129 129  * Maximum SOC – maximum cell SOC value for resistance calculation.
130 130  
131 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see section 2.3.1). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
132 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
132 132  
133 133  === Low SOC (signal) ===
134 134  
... ... @@ -570,7 +570,7 @@
570 570  ** Balance on charge or relaxed - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states);
571 571  ** Balance always – balancing is always performed regardless the battery state;
572 572  
573 -[[image:1733322883462-975.png]]
574 +[[image:1733322883462-975.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="74" width="600"]]
574 574  
575 575  * Minimum cell voltage to start balancing, V;
576 576  * Voltage deviation to start balancing;