Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 39.1
edited by Admin
on 2025/02/14 11:41
Change comment: There is no comment for this version
To version 37.1
edited by Admin
on 2025/02/11 16:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -597,10 +597,10 @@
597 597  * Switch off the discharging (AUX) contactor if the SOC is too low;
598 598  * Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %;
599 599  * Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %;
600 -* Switch off the discharging (AUX) contactor if the cell voltage is out of the range;
601 -* Minimum cell voltage, V;
602 -* Maximum cell voltage, V;
603 603  * Switch off the discharging (AUX) contactor if the battery voltage is out of the range;
601 +* Minimum voltage – minimum battery voltage, V;
602 +* Maximum voltage – maximum battery voltage, V;
603 +* Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error;
604 604  * Minimum battery voltage, V;
605 605  * Maximum battery voltage, V;
606 606  * Errors 1, 2 to open the auxiliary discharging contactor – bitfields to choose the errors which will open the auxiliary discharging contactor;
... ... @@ -728,10 +728,7 @@
728 728  
729 729  * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time.
730 730  
731 -(% class="box infomessage" %)
732 -(((
733 733  If there is the "Heater" signal, the heater contactor closes and/or a signal is set to the corresponding digital output.
734 -)))
735 735  
736 736  === Cooler ===
737 737  
... ... @@ -758,10 +758,7 @@
758 758  
759 759  * the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time.
760 760  
761 -(% class="box infomessage" %)
762 -(((
763 763  If there is the "Cooler" signal, the cooler contactor closes and/or a signal is set to the corresponding digital output.
764 -)))
765 765  
766 766  === High voltage ===
767 767