Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -597,10 +597,10 @@ 597 597 * Switch off the discharging (AUX) contactor if the SOC is too low; 598 598 * Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 599 599 * Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 600 +* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 601 +* Minimum cell voltage, V; 602 +* Maximum cell voltage, V; 600 600 * Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 601 -* Minimum voltage – minimum battery voltage, V; 602 -* Maximum voltage – maximum battery voltage, V; 603 -* Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error; 604 604 * Minimum battery voltage, V; 605 605 * Maximum battery voltage, V; 606 606 * Errors 1, 2 to open the auxiliary discharging contactor – bitfields to choose the errors which will open the auxiliary discharging contactor;