Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -503,7 +503,7 @@ 503 503 504 504 When the "**On discharge request**" algorithm selected, the control is performed as follows: 505 505 506 -* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the listabove), then through the delay time T,,on,, the discharging contactor closes;506 +* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes; 507 507 * If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 508 508 509 509 (% class="box infomessage" %) ... ... @@ -511,7 +511,7 @@ 511 511 **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 512 512 ))) 513 513 514 -The device supports controlling the precharging contactor .The duration ofswitching on theprecharging contactorbeforelosing the discharging (load) contactor is adjusted.514 +The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]). 515 515 516 516 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 517 517 ... ... @@ -580,7 +580,7 @@ 580 580 581 581 * the battery has low SOC; 582 582 * the battery voltage is out of range; 583 -* the battery system errors are detected.583 +* the errors are detected (configured in the "Errors 1, 2 ..." bitfields). 584 584 585 585 (% class="box infomessage" %) 586 586 ((( ... ... @@ -728,7 +728,7 @@ 728 728 729 729 * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 730 730 731 -If there is the "Heater" signal, the heater contactor closes and/or a signal is outputto the corresponding digital output.731 +If there is the "Heater" signal, the heater contactor closes and/or a signal is set to the corresponding digital output. 732 732 733 733 === Cooler === 734 734 ... ... @@ -755,7 +755,7 @@ 755 755 756 756 * the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 757 757 758 -If there is the "Cooler" signal, the cooler contactor closes and/or a signal is outputto the corresponding digital output.758 +If there is the "Cooler" signal, the cooler contactor closes and/or a signal is set to the corresponding digital output. 759 759 760 760 === High voltage === 761 761