Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 33.8
edited by Admin
on 2025/02/11 13:25
Change comment: There is no comment for this version
To version 33.3
edited by Admin
on 2025/02/11 13:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -431,8 +431,24 @@
431 431  * On charger connected – charging is allowed when there is a signal “Charger connected”;
432 432  * On charge request – charging is allowed when there is a signal “Charge request”.
433 433  
434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
435 435  
436 +* Overvoltage;
437 +* Overcurrent;
438 +* High temperature (CH);
439 +* Low temperature (CH);
440 +* HYG offline (optional);
441 +* Combilift offline (optional);
442 +* Spirit offline (optional);
443 +* Spirit charger error (optional);
444 +* Short circuit (optional);
445 +* High contactor temperature (optional);
446 +* CH contactor cycles error;
447 +* Precharge error (optional);
448 +* Critical error
449 +
450 +or one of the signals:
451 +
436 436  * Service reset;
437 437  * Power down request;
438 438  * Inhibit charging,
... ... @@ -441,17 +441,17 @@
441 441  
442 442  When the algorithm "**On charger connected**" is selected, the control is performed as follows:
443 443  
444 -* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
460 +* If there is a signal “Charger connected” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
445 445  * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
446 446  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
447 -* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
463 +* If errors in the list above occur the charging contactor and allow charging contactor open.
448 448  
449 449  When the "**On charge request**" algorithm selected, the control is performed as follows:
450 450  
451 -* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
467 +* If there is a signal “Charge request” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
452 452  * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
453 453  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
454 -* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
470 +* If errors in the list above occur the charging contactor and allow charging contactor open.
455 455  
456 456  (% class="box infomessage" %)
457 457  (((
... ... @@ -488,8 +488,26 @@
488 488  * On charger disconnected – load is connected when there is no signal “Charger connected”;
489 489  * On discharge request – load is connected when there is signal “Discharge request”.
490 490  
491 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
507 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears:
492 492  
509 +* Undervoltage;
510 +* Overvoltage (optional);
511 +* Overcurrent;
512 +* High temperature (DCH);
513 +* Low temperature (DCH) (optional);
514 +* HYG offline (optional);
515 +* Combilift offline (optional);
516 +* Spirit offline (optional);
517 +* Spirit charger error (optional);
518 +* Short circuit (optional);
519 +* High contactor temperature (optional);
520 +* Unallowable charging;
521 +* DCH contactor cycles error;
522 +* Precharge error (optional);
523 +* Critical error
524 +
525 +or one of the signals:
526 +
493 493  * Service reset
494 494  * Power down request
495 495  * Inhibit discharging
... ... @@ -498,13 +498,13 @@
498 498  
499 499  If the algorithm "**On charger disconnected**" is selected, the control is performed as follows:
500 500  
501 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes;
502 -* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
535 +* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
536 +* If the signal “Charger connected” appears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
503 503  
504 504  When the "**On discharge request**" algorithm selected, the control is performed as follows:
505 505  
506 506  * if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
507 -* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
541 +* If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
508 508  
509 509  (% class="box infomessage" %)
510 510  (((