Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -70,7 +70,7 @@ 70 70 71 71 * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells; 72 72 * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC; 73 -* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell ha ve100% SOC, b) 0% if any cell have0% SOC;73 +* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC; 74 74 * Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC; 75 75 76 76 Other parameters: ... ... @@ -410,10 +410,10 @@ 410 410 * Delay before clearing the "Precharge error", second; 411 411 * Lock the "Precharge error" – a flag to block the error until the device is restarted. 412 412 413 -“Precharge error” generation conditions: 413 +“Precharge error” generation conditions if any of the following is true: 414 414 415 -* the precharge current does not decrease after "Number of precharging attempts"; 416 -* voltages before and after contactors are not equal after "Number of precharging attempts"; 415 +* the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 416 +* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts"; 417 417 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 418 418 419 419 (% class="box warningmessage" %) ... ... @@ -451,7 +451,7 @@ 451 451 * If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 452 452 * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 453 453 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 454 -* If errors inthelistabove occur the charging contactor and allow charging contactor open.454 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 455 455 456 456 (% class="box infomessage" %) 457 457 ((( ... ... @@ -488,26 +488,8 @@ 488 488 * On charger disconnected – load is connected when there is no signal “Charger connected”; 489 489 * On discharge request – load is connected when there is signal “Discharge request”. 490 490 491 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears: 491 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 492 492 493 -* Undervoltage; 494 -* Overvoltage (optional); 495 -* Overcurrent; 496 -* High temperature (DCH); 497 -* Low temperature (DCH) (optional); 498 -* HYG offline (optional); 499 -* Combilift offline (optional); 500 -* Spirit offline (optional); 501 -* Spirit charger error (optional); 502 -* Short circuit (optional); 503 -* High contactor temperature (optional); 504 -* Unallowable charging; 505 -* DCH contactor cycles error; 506 -* Precharge error (optional); 507 -* Critical error 508 - 509 -or one of the signals: 510 - 511 511 * Service reset 512 512 * Power down request 513 513 * Inhibit discharging ... ... @@ -516,13 +516,13 @@ 516 516 517 517 If the algorithm "**On charger disconnected**" is selected, the control is performed as follows: 518 518 519 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the listabove), then through the delay time T,,on,, the discharging contactor closes;520 -* If the signal “Charger connected” appears or errors occur (see the listabove), then after the delay time T,,off,, the discharging contactor opens.501 +* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes; 502 +* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 521 521 522 522 When the "**On discharge request**" algorithm selected, the control is performed as follows: 523 523 524 -* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the listabove), then through the delay time T,,on,, the discharging contactor closes;525 -* If the signal “Discharge request” disappears or errors occur (see the listabove), then after the delay time T,,off,, the discharging contactor opens.506 +* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes; 507 +* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 526 526 527 527 (% class="box infomessage" %) 528 528 ((( ... ... @@ -529,7 +529,7 @@ 529 529 **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 530 530 ))) 531 531 532 -The device supports controlling the precharging contactor .The duration ofswitching on theprecharging contactorbeforelosing the discharging (load) contactor is adjusted.514 +The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]). 533 533 534 534 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 535 535 ... ... @@ -598,7 +598,7 @@ 598 598 599 599 * the battery has low SOC; 600 600 * the battery voltage is out of range; 601 -* the battery system errors are detected.583 +* the errors are detected (configured in the "Errors 1, 2 ..." bitfields). 602 602 603 603 (% class="box infomessage" %) 604 604 ((( ... ... @@ -615,10 +615,10 @@ 615 615 * Switch off the discharging (AUX) contactor if the SOC is too low; 616 616 * Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 617 617 * Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 600 +* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 601 +* Minimum cell voltage, V; 602 +* Maximum cell voltage, V; 618 618 * Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 619 -* Minimum voltage – minimum battery voltage, V; 620 -* Maximum voltage – maximum battery voltage, V; 621 -* Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error; 622 622 * Minimum battery voltage, V; 623 623 * Maximum battery voltage, V; 624 624 * Errors 1, 2 to open the auxiliary discharging contactor – bitfields to choose the errors which will open the auxiliary discharging contactor; ... ... @@ -636,7 +636,7 @@ 636 636 A balancing resistor is connected to the cell if the following conditions are simultaneously met: 637 637 638 638 * the voltage on the cell is higher than the balancing start voltage; 639 -* the difference between the voltage on the cell and the minimum voltage among the battery cells is greater than the balancing start threshold .621 +* the difference between the voltage on the cell and the minimum voltage among the battery cells is greater than the balancing start threshold; 640 640 641 641 A balancing resistor is disconnected from the cell if any of the following conditions are met: 642 642 ... ... @@ -647,6 +647,8 @@ 647 647 648 648 The BMS Main 3 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 649 649 632 +BMS Main 3 can force a cell balancing, if its voltage is higher than 633 + 650 650 To change the cell balancing parameters, select the "Control → Cell balancing" section: 651 651 652 652 [[image:1735065702806-422.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]] ... ... @@ -746,7 +746,10 @@ 746 746 747 747 * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 748 748 749 -If there is the "Heater" signal, the heater contactor closes and/or a signal is output to the corresponding digital output. 733 +(% class="box infomessage" %) 734 +((( 735 +If there is the "Heater" signal, the heater contactor closes and/or a signal is set to the corresponding digital output. 736 +))) 750 750 751 751 === Cooler === 752 752 ... ... @@ -773,7 +773,10 @@ 773 773 774 774 * the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 775 775 776 -If there is the "Cooler" signal, the cooler contactor closes and/or a signal is output to the corresponding digital output. 763 +(% class="box infomessage" %) 764 +((( 765 +If there is the "Cooler" signal, the cooler contactor closes and/or a signal is set to the corresponding digital output. 766 +))) 777 777 778 778 === High voltage === 779 779