Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -451,7 +451,7 @@ 451 451 * If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 452 452 * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 453 453 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 454 -* If errors inthelistabove occur the charging contactor and allow charging contactor open.454 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 455 455 456 456 (% class="box infomessage" %) 457 457 ((( ... ... @@ -488,26 +488,8 @@ 488 488 * On charger disconnected – load is connected when there is no signal “Charger connected”; 489 489 * On discharge request – load is connected when there is signal “Discharge request”. 490 490 491 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears: 491 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 492 492 493 -* Undervoltage; 494 -* Overvoltage (optional); 495 -* Overcurrent; 496 -* High temperature (DCH); 497 -* Low temperature (DCH) (optional); 498 -* HYG offline (optional); 499 -* Combilift offline (optional); 500 -* Spirit offline (optional); 501 -* Spirit charger error (optional); 502 -* Short circuit (optional); 503 -* High contactor temperature (optional); 504 -* Unallowable charging; 505 -* DCH contactor cycles error; 506 -* Precharge error (optional); 507 -* Critical error 508 - 509 -or one of the signals: 510 - 511 511 * Service reset 512 512 * Power down request 513 513 * Inhibit discharging ... ... @@ -516,13 +516,13 @@ 516 516 517 517 If the algorithm "**On charger disconnected**" is selected, the control is performed as follows: 518 518 519 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the listabove), then through the delay time T,,on,, the discharging contactor closes;520 -* If the signal “Charger connected” appears or errors occur (see the listabove), then after the delay time T,,off,, the discharging contactor opens.501 +* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes; 502 +* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 521 521 522 522 When the "**On discharge request**" algorithm selected, the control is performed as follows: 523 523 524 524 * if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes; 525 -* If the signal “Discharge request” disappears or errors occur (see the listabove), then after the delay time T,,off,, the discharging contactor opens.507 +* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 526 526 527 527 (% class="box infomessage" %) 528 528 (((