Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -431,13 +431,29 @@ 431 431 * On charger connected – charging is allowed when there is a signal “Charger connected”; 432 432 * On charge request – charging is allowed when there is a signal “Charge request”. 433 433 434 -If the "**Always on**" algorithm is selected, the charging contactor i salways closed. If at least one of the errorsfrom the "Errors 1, 2 ..." bitfieldappearsor one of the signals:434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears: 435 435 436 +* Overvoltage; 437 +* Overcurrent; 438 +* High temperature (CH); 439 +* Low temperature (CH); 440 +* HYG offline (optional); 441 +* Combilift offline (optional); 442 +* Spirit offline (optional); 443 +* Spirit charger error (optional); 444 +* Short circuit (optional); 445 +* High contactor temperature (optional); 446 +* CH contactor cycles error; 447 +* Precharge error (optional); 448 +* Critical error 449 + 450 +or one of the signals: 451 + 436 436 * Service reset; 437 437 * Power down request; 438 438 * Inhibit charging, 439 439 440 -contactor are open (no current flows). 456 +both contactors are open (no current flows). 441 441 442 442 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 443 443