Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -328,7 +328,7 @@ 328 328 * Other contactors are open; 329 329 * There is an error from the the "Errors 1, 2 ..." bitfileds. 330 330 331 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.331 +In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with ther contactors. 332 332 333 333 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 334 334 ... ... @@ -431,13 +431,29 @@ 431 431 * On charger connected – charging is allowed when there is a signal “Charger connected”; 432 432 * On charge request – charging is allowed when there is a signal “Charge request”. 433 433 434 -If the "**Always on**" algorithm is selected, the charging contactor i salways closed. If at least one of the errorsfrom the "Errors 1, 2 ..." bitfieldsappearsor one of the signals:434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears: 435 435 436 +* Overvoltage; 437 +* Overcurrent; 438 +* High temperature (CH); 439 +* Low temperature (CH); 440 +* HYG offline (optional); 441 +* Combilift offline (optional); 442 +* Spirit offline (optional); 443 +* Spirit charger error (optional); 444 +* Short circuit (optional); 445 +* High contactor temperature (optional); 446 +* CH contactor cycles error; 447 +* Precharge error (optional); 448 +* Critical error 449 + 450 +or one of the signals: 451 + 436 436 * Service reset; 437 437 * Power down request; 438 438 * Inhibit charging, 439 439 440 -contactor open s(no current flows).456 +both contactors are open (no current flows). 441 441 442 442 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 443 443