Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -431,24 +431,8 @@ 431 431 * On charger connected – charging is allowed when there is a signal “Charger connected”; 432 432 * On charge request – charging is allowed when there is a signal “Charge request”. 433 433 434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears: 434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 435 435 436 -* Overvoltage; 437 -* Overcurrent; 438 -* High temperature (CH); 439 -* Low temperature (CH); 440 -* HYG offline (optional); 441 -* Combilift offline (optional); 442 -* Spirit offline (optional); 443 -* Spirit charger error (optional); 444 -* Short circuit (optional); 445 -* High contactor temperature (optional); 446 -* CH contactor cycles error; 447 -* Precharge error (optional); 448 -* Critical error 449 - 450 -or one of the signals: 451 - 452 452 * Service reset; 453 453 * Power down request; 454 454 * Inhibit charging, ... ... @@ -457,14 +457,14 @@ 457 457 458 458 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 459 459 460 -* If there is a signal “Charger connected” and there are no errors (see the listabove), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;444 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 461 461 * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 462 462 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 463 -* If errors inthelistabove occur the charging contactor and allow charging contactor open.447 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 464 464 465 465 When the "**On charge request**" algorithm selected, the control is performed as follows: 466 466 467 -* If there is a signal “Charge request” and there are no errors (see the listabove), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;451 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 468 468 * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 469 469 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 470 470 * If errors in the list above occur the charging contactor and allow charging contactor open.