Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -431,29 +431,13 @@ 431 431 * On charger connected – charging is allowed when there is a signal “Charger connected”; 432 432 * On charge request – charging is allowed when there is a signal “Charge request”. 433 433 434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow chargingcontactor are always closed. If at least one of the errors appears:434 +If the "**Always on**" algorithm is selected, the charging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfield appears or one of the signals: 435 435 436 -* Overvoltage; 437 -* Overcurrent; 438 -* High temperature (CH); 439 -* Low temperature (CH); 440 -* HYG offline (optional); 441 -* Combilift offline (optional); 442 -* Spirit offline (optional); 443 -* Spirit charger error (optional); 444 -* Short circuit (optional); 445 -* High contactor temperature (optional); 446 -* CH contactor cycles error; 447 -* Precharge error (optional); 448 -* Critical error 449 - 450 -or one of the signals: 451 - 452 452 * Service reset; 453 453 * Power down request; 454 454 * Inhibit charging, 455 455 456 - bothcontactorsare open (no current flows).440 +contactor are open (no current flows). 457 457 458 458 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 459 459