Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 33.2
edited by Admin
on 2025/02/11 13:18
Change comment: There is no comment for this version
To version 33.8
edited by Admin
on 2025/02/11 13:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -328,7 +328,7 @@
328 328  * Other contactors are open;
329 329  * There is an error from the the "Errors 1, 2 ..." bitfileds.
330 330  
331 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with ther contactors.
331 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
332 332  
333 333  In “On demand” mode, the main contactor closes by external the “Close Main contactor” request.
334 334  
... ... @@ -431,24 +431,8 @@
431 431  * On charger connected – charging is allowed when there is a signal “Charger connected”;
432 432  * On charge request – charging is allowed when there is a signal “Charge request”.
433 433  
434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
435 435  
436 -* Overvoltage;
437 -* Overcurrent;
438 -* High temperature (CH);
439 -* Low temperature (CH);
440 -* HYG offline (optional);
441 -* Combilift offline (optional);
442 -* Spirit offline (optional);
443 -* Spirit charger error (optional);
444 -* Short circuit (optional);
445 -* High contactor temperature (optional);
446 -* CH contactor cycles error;
447 -* Precharge error (optional);
448 -* Critical error
449 -
450 -or one of the signals:
451 -
452 452  * Service reset;
453 453  * Power down request;
454 454  * Inhibit charging,
... ... @@ -457,17 +457,17 @@
457 457  
458 458  When the algorithm "**On charger connected**" is selected, the control is performed as follows:
459 459  
460 -* If there is a signal “Charger connected” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
444 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
461 461  * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
462 462  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
463 -* If errors in the list above occur the charging contactor and allow charging contactor open.
447 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
464 464  
465 465  When the "**On charge request**" algorithm selected, the control is performed as follows:
466 466  
467 -* If there is a signal “Charge request” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
451 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
468 468  * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
469 469  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
470 -* If errors in the list above occur the charging contactor and allow charging contactor open.
454 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
471 471  
472 472  (% class="box infomessage" %)
473 473  (((
... ... @@ -504,26 +504,8 @@
504 504  * On charger disconnected – load is connected when there is no signal “Charger connected”;
505 505  * On discharge request – load is connected when there is signal “Discharge request”.
506 506  
507 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears:
491 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
508 508  
509 -* Undervoltage;
510 -* Overvoltage (optional);
511 -* Overcurrent;
512 -* High temperature (DCH);
513 -* Low temperature (DCH) (optional);
514 -* HYG offline (optional);
515 -* Combilift offline (optional);
516 -* Spirit offline (optional);
517 -* Spirit charger error (optional);
518 -* Short circuit (optional);
519 -* High contactor temperature (optional);
520 -* Unallowable charging;
521 -* DCH contactor cycles error;
522 -* Precharge error (optional);
523 -* Critical error
524 -
525 -or one of the signals:
526 -
527 527  * Service reset
528 528  * Power down request
529 529  * Inhibit discharging
... ... @@ -532,13 +532,13 @@
532 532  
533 533  If the algorithm "**On charger disconnected**" is selected, the control is performed as follows:
534 534  
535 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
536 -* If the signal “Charger connected” appears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
501 +* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes;
502 +* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
537 537  
538 538  When the "**On discharge request**" algorithm selected, the control is performed as follows:
539 539  
540 540  * if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
541 -* If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
507 +* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
542 542  
543 543  (% class="box infomessage" %)
544 544  (((