Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -328,7 +328,7 @@ 328 328 * Other contactors are open; 329 329 * There is an error from the the "Errors 1, 2 ..." bitfileds. 330 330 331 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with ther contactors.331 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 332 332 333 333 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 334 334 ... ... @@ -431,24 +431,8 @@ 431 431 * On charger connected – charging is allowed when there is a signal “Charger connected”; 432 432 * On charge request – charging is allowed when there is a signal “Charge request”. 433 433 434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears: 434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 435 435 436 -* Overvoltage; 437 -* Overcurrent; 438 -* High temperature (CH); 439 -* Low temperature (CH); 440 -* HYG offline (optional); 441 -* Combilift offline (optional); 442 -* Spirit offline (optional); 443 -* Spirit charger error (optional); 444 -* Short circuit (optional); 445 -* High contactor temperature (optional); 446 -* CH contactor cycles error; 447 -* Precharge error (optional); 448 -* Critical error 449 - 450 -or one of the signals: 451 - 452 452 * Service reset; 453 453 * Power down request; 454 454 * Inhibit charging, ... ... @@ -457,14 +457,14 @@ 457 457 458 458 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 459 459 460 -* If there is a signal “Charger connected” and there are no errors (see the listabove), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;444 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 461 461 * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 462 462 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 463 -* If errors inthelistabove occur the charging contactor and allow charging contactor open.447 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 464 464 465 465 When the "**On charge request**" algorithm selected, the control is performed as follows: 466 466 467 -* If there is a signal “Charge request” and there are no errors (see the listabove), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;451 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 468 468 * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 469 469 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 470 470 * If errors in the list above occur the charging contactor and allow charging contactor open.