Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 33.2
edited by Admin
on 2025/02/11 13:18
Change comment: There is no comment for this version
To version 33.4
edited by Admin
on 2025/02/11 13:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -328,7 +328,7 @@
328 328  * Other contactors are open;
329 329  * There is an error from the the "Errors 1, 2 ..." bitfileds.
330 330  
331 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with ther contactors.
331 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
332 332  
333 333  In “On demand” mode, the main contactor closes by external the “Close Main contactor” request.
334 334  
... ... @@ -431,29 +431,13 @@
431 431  * On charger connected – charging is allowed when there is a signal “Charger connected”;
432 432  * On charge request – charging is allowed when there is a signal “Charge request”.
433 433  
434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
434 +If the "**Always on**" algorithm is selected, the charging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfield appears or one of the signals:
435 435  
436 -* Overvoltage;
437 -* Overcurrent;
438 -* High temperature (CH);
439 -* Low temperature (CH);
440 -* HYG offline (optional);
441 -* Combilift offline (optional);
442 -* Spirit offline (optional);
443 -* Spirit charger error (optional);
444 -* Short circuit (optional);
445 -* High contactor temperature (optional);
446 -* CH contactor cycles error;
447 -* Precharge error (optional);
448 -* Critical error
449 -
450 -or one of the signals:
451 -
452 452  * Service reset;
453 453  * Power down request;
454 454  * Inhibit charging,
455 455  
456 -both contactors are open (no current flows).
440 +contactor open (no current flows).
457 457  
458 458  When the algorithm "**On charger connected**" is selected, the control is performed as follows:
459 459